MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20150928-02

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2015

Screening Patients With Cataract for Premium IOL Candidacy Using Microperimetry.

Klyce Stephen D, McDonald Marguerite B, Morales Marco U

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the use of microperimetry in the evaluation of macular dysfunction in patients with cataract, to aid in proper intraocular lens selection (multifocal vs monofocal), and to set expectations for postoperative visual function.

METHODS

One randomly chosen eye of 10 patients diagnosed as having mild (1+) to moderate (3+) cataract was evaluated before and 1 week after cataract surgery with the MAIA microperimeter (Centervue S.p.A, Padova, Italy). Corrected distance visual acuity, dilated and undilated biomicroscopy and indirect fundus examinations, intraocular pressure measurement, and a MAIA microperimeter test to measure macular sensitivity and fixation pattern were also performed.

RESULTS

Two patients showed macular abnormalities before and after surgery that were noted on MAIA testing: one patient showed reduced average threshold sensitivity and abnormal percent reduced threshold, whereas the other patient showed fixation drift demonstrating eccentric fixation. Both eyes had reduced postoperative visual performance after uneventful cataract surgeries.

CONCLUSIONS

Because not every macular lesion noted on fundus examination or optical coherence tomography may be clinically significant, microperimetry can be useful to detect clinically significant retinal dysfunction prior to cataract surgery. The outcome may aid in the selection of intraocular lens type and may yield a better documented surgical prognosis. Further studies are necessary to confirm these findings.

Для цитирования: Klyce Stephen D, McDonald Marguerite B, Morales Marco U. Screening Patients With Cataract for Premium IOL Candidacy Using Microperimetry.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2015. DOI: 10.3928/1081597x-20150928-02.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.