Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification.
Аннотация
AIM: To compare the degree of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods during an 8-year follow-up period using two types of software.
DESIGN
Prospective, randomized clinical trial.
METHODS
AquaLase was used in the right eye and NeoSoniX in the left eye of each patient with bilateral cataract.
RESULTS
Fifty patients were analyzed 1 year, 46 patients 3 years, and 37 patients 8 years after cataract surgery. Mean EPCO 2000 values were for the AquaLase group 0.324 ± 0.305 and for the NeoSoniX group 0.298 ± 0.341 (P = 0.53) 1 year after surgery, for the AquaLase group 0.582 ± 0.506 and for the NeoSoniX group 0.594 ± 0.515 (P = 0.87) 3 years after surgery, and for the AquaLase group 0.648 ± 0.567 and for the NeoSoniX group 0.673 ± 0.542 (P = 0.30) 8 years after surgery. The OSCA results were for the AquaLase group 0.7097 ± 0.3778 and for the NeoSoniX group 0.8584 ± 0.4323 (P = 0.046) 1 year after surgery, for the AquaLase group 0.9667 ± 0.736 and for the NeoSoniX group 0.9540 ± 0.5250 (P = 0.91) 3 years after surgery, and for the AquaLase group 1,035 ± 0,952 and for the NeoSoniX group 1,103 ± 0,741 (P = 0.44) 8 years after surgery.
CONCLUSION
There was minimal PCO difference between these 2 approaches, AquaLase and NeoSoniX. Neither AquaLase nor NeoSoniX technique was able to prevent a natural progression of PCO.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.