MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5507/bp.2015.039

Медицинская библиотека · Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia · 2015

Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification.

Stepanov Alexandr, Nekolova Jana, Jiraskova Nada, Rozsival Pavel

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIM: To compare the degree of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods during an 8-year follow-up period using two types of software.

DESIGN

Prospective, randomized clinical trial.

METHODS

AquaLase was used in the right eye and NeoSoniX in the left eye of each patient with bilateral cataract.

RESULTS

Fifty patients were analyzed 1 year, 46 patients 3 years, and 37 patients 8 years after cataract surgery. Mean EPCO 2000 values were for the AquaLase group 0.324 ± 0.305 and for the NeoSoniX group 0.298 ± 0.341 (P = 0.53) 1 year after surgery, for the AquaLase group 0.582 ± 0.506 and for the NeoSoniX group 0.594 ± 0.515 (P = 0.87) 3 years after surgery, and for the AquaLase group 0.648 ± 0.567 and for the NeoSoniX group 0.673 ± 0.542 (P = 0.30) 8 years after surgery. The OSCA results were for the AquaLase group 0.7097 ± 0.3778 and for the NeoSoniX group 0.8584 ± 0.4323 (P = 0.046) 1 year after surgery, for the AquaLase group 0.9667 ± 0.736 and for the NeoSoniX group 0.9540 ± 0.5250 (P = 0.91) 3 years after surgery, and for the AquaLase group 1,035 ± 0,952 and for the NeoSoniX group 1,103 ± 0,741 (P = 0.44) 8 years after surgery.

CONCLUSION

There was minimal PCO difference between these 2 approaches, AquaLase and NeoSoniX. Neither AquaLase nor NeoSoniX technique was able to prevent a natural progression of PCO.

Для цитирования: Stepanov Alexandr, Nekolova Jana, Jiraskova Nada, Rozsival Pavel. Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification.. Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia. 2015. DOI: 10.5507/bp.2015.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.