MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5301/ejo.5000653

Медицинская библиотека · European journal of ophthalmology · 2015

Clinical experience with the WIOL-CF accommodative bioanalogic intraocular lens: Czech national observational registry.

Studeny Pavel, Krizova Deli, Urminsky Juraj

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To assess efficacy and patient satisfaction after cataract surgery and implantation of a new accommodative bioanalogic intraocular lens (IOL).

METHODS

We evaluated the collected data of 48 patients with bilateral cataract surgery and Wichterle IOL (WIOL) implantation included in the Czech national observational registry. Monocular and binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity, uncorrected near visual acuity (UNVA), best spectacle-corrected visual acuity for distance (CDVA), best spectacle-corrected visual acuity for near (CNVA), distance-corrected near visual acuity (DCNVA), and distance-corrected intermediate visual acuity were evaluated 6 months after surgery. Subjective patient satisfaction was assessed at 3 months postoperatively.

RESULTS

The mean monocular UDVA was 0.074 ± 0.108 logMAR, the mean monocular CDVA was 0.047 ± 0.125 logMAR, the mean monocular UNVA was 0.328 ± 0.146 logMAR, the mean monocular DCNVA was 0.339 ± 0.131 logMAR, and the mean monocular CNVA was 0.139 ± 0.107 logMAR. A total of 24 patients (50%) had no problems with any light phenomena. A total of 18 patients were very satisfied (37.5%), 11 were satisfied (22.9%), 15 (31.2%) were rather satisfied, 4 (8.3%) were rather dissatisfied, and 0 were dissatisfied.

CONCLUSIONS

The WIOL-continuous focus polyfocal lens offers very good vision at far and intermediate distance comparable with other types of multifocal IOLs, and relatively good near vision, while the incidence of adverse side phenomena is relatively low.

Для цитирования: Studeny Pavel, Krizova Deli, Urminsky Juraj. Clinical experience with the WIOL-CF accommodative bioanalogic intraocular lens: Czech national observational registry.. European journal of ophthalmology. 2015. DOI: 10.5301/ejo.5000653.