m+Medelevator.RU
← Поиск публикаций
Clinical ophthalmology (Auckland, N.Z.) · 2015

The role of sideport incision in astigmatism change after cataract surgery.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Theodoulidou Sofia, Asproudis Ioannis, Kalogeropoulos Christos, Athanasiadis Aristidis, Aspiotis Miltiadis

Аннотация

PURPOSE: To study the changes in corneal astigmatism after cataract surgery when the sideport incision is performed at a predetermined location away from the tunnel incision.

SETTING: General Hospital of Piraeus "Tzaneio", Attiki, Greece.

MATERIALS AND METHODS: A total of 333 eyes with corneal astigmatism ≤1.5 diopters (D) underwent cataract surgery. A three-step superotemporal clear corneal incision for the right eye and a superonasal clear corneal incision for the left eye (3.0 mm) was made, while the sideport incision was located at <90°, 90°-110°, and >110°. Keratometric data were measured with corneal topography EyeSys Vista 2000 pre- and postoperatively at the 1st and 6th month. Surgically induced astigmatism was calculated by vector analysis. We noted all cases in which a change >0.5 D in corneal astigmatic power occurred, as well as a change >20° in axis torque, despite axis direction.

RESULTS: After multiple logistic regression analysis was conducted, cases with >110° distance between the tunnel and sideport incision had 2.22 times (P=0.021) greater likelihood for having changed >0.5 D in astigmatic power at the 1st month and 3.45 times (P=0.031) at the 6th month postoperatively, as compared with cases with a 90°-110° distance between the tunnel and sideport incision. As for the change in the astigmatic axis, cases with <90° distance had a 4.18 times greater likelihood for having a change >20° (P<0.001) (preoperative to 1st month) as compared with cases having 90°-110° of distance.

CONCLUSION: For surgeons that operate only from the superior position, we propose that in order to produce an incision that is as "astigmatically neutral" as possible, they should perform the sideport incision at a 90°-110° distance.