m+Medelevator.RU
← Поиск публикаций
Frontiers in cardiovascular medicine · 2025

Case Report: Aveir implantation in an 8.7-year-old, 25-kg pediatric patient with mitochondrial disease via internal jugular vein.

Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhou Xue, Xu Xin, He Shuang, Liu Qian, Lu Tiewei

Аннотация

INTRODUCTION: Mitochondrial disorders frequently precipitate progressive conduction system degeneration, with complete heart block representing a critical therapeutic challenge in pediatric populations, which ultimately requires permanent pacemaker implantation. However transjugular venous implantation of the Aveir leadless pacemaker in a pediatric patient with mitochondrial disease has not been previously reported.

METHODS AND RESULTS: An 8.7-year-old, female patient (weight: 25 kg) with genetically confirmed mitochondrial disease presented with cardiac syncope secondary to the complete atrioventricular block. Comorbidities included insulin-dependent diabetes and pocket infection from a conventional permanent pacemaker implanted four months prior. Given her history of device-related complications and restricted venous access, a retrievable leadless pacemaker (Abbott Aveir) was successfully implanted via the internal jugular vein under fluoroscopic guidance without complication. Stability testing confirmed adequate fixation with pacing threshold of 1.0V@0.2 ms and impedance of 610Ω at one-month follow-up.

CONCLUSION: The Aveir VR leadless pacemaker can be safely implanted via the internal jugular vein approach in pediatric patients with mitochondrial disease.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты