Electrical impedance spectroscopy facilitates quantitative depth monitoring of pulsed field ablation: An impedimetric approach with preclinical validation.

Guo Yuyi, Han Rui, Liu Rongrong, Zhu Kai, Guo Jinsong, Rao Junfeng, Wang Qun, Zhao Qiancheng, Shi Fukun, Zhuang Jie

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulsed field ablation (PFA) is an emerging therapy for cardiac ablation, where ablation depth (D) is critical to procedural success. However, real-time intra-procedural assessment of D remains a challenging task.

OBJECTIVE

Electrical impedance spectroscopy (EIS) has been proposed to predict the ablation zone, but its applicability and mechanism for quantifying D is still unclear.

METHODS

Monopolar and bipolar PFA were conducted via 2 catheter types, along with in situ EIS measurements. The change rate of low-frequency resistance (LFR), derived from Cole-Cole modeling of EIS data, was used to evaluate D in both in vitro (205 potato samples) and in vivo canine models (n = 5).

RESULTS

LFR vs Ds followed a classical Gompertz growth model within 0∼15 mm (R2 = 0.8789). A quadratic function provided a good fit for evaluating Ds within 1∼9 mm (R2 = 0.7561). Furthermore, LFR5min could detect a depth difference of approximately 0.8 mm in canine cardiac ablation (P = .0003).

CONCLUSIONS

LFR5min robustly correlated with PFA lesion depth, fitting quantitative quadratic and Gompertz models. Validated in vivo in a clinically relevant canine cardiac model, LFR5min resolved sub-millimeter depth differences, positioning it as a promising intra-operative metric for real-time PFA guidance.

Для цитирования: Guo Yuyi, Han Rui, Liu Rongrong, Zhu Kai, Guo Jinsong, Rao Junfeng, Wang Qun, Zhao Qiancheng, Shi Fukun, Zhuang Jie. Electrical impedance spectroscopy facilitates quantitative depth monitoring of pulsed field ablation: An impedimetric approach with preclinical validation.. Heart rhythm. 2025. DOI: 10.1016/j.hrthm.2025.09.034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.