m+Medelevator.RU
← Поиск публикаций
The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2020

Impact of left ventricular assist device implantation on mitral regurgitation: An analysis from the MOMENTUM 3 trial.

СтатьяМногоцентровое исследованиеРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kanwar Manreet K, Rajagopal Keshava, Itoh Akinobu, Silvestry Scott C, Uriel Nir, Cleveland Joseph C, Salerno Christopher T, Horstmanshof Douglas, Goldstein Daniel J, Naka Yoshifumi, Bailey Stephen, Gregoric Igor D, Chuang Joyce, Sood Poornima, Mehra Mandeep R

Аннотация

BACKGROUND: Mitral regurgitation (MR) determines pathophysiology and outcome in advanced heart failure. The impact of left ventricular assist device (LVAD) placement on clinically significant MR and its contribution to long-term outcomes has been sparsely evaluated.

METHODS: We evaluated the effect of clinically significant MR on patients implanted in the MOMENTUM 3 trial with either the HeartMate II (HMII) or the HeartMate 3 (HM3) at 2 years. Clinical significance was defined as moderate or severe grade MR determined by site-based echocardiograms.

RESULTS: Of 927 patients with LVAD implants without a prior or concomitant mitral valve procedure, 403 (43.5%) had clinically significant MR at baseline. At 1-month of support, residual MR was present in 6.2% of patients with HM3 and 14.3% of patients with HMII (relative risk = 0.43; 95% CI, 0.22-0.84; p = 0.01) with a low rate of worsening at 2 years. Residual MR at 1-month post-implant did not impact 2-year mortality for either the HM3 (hazard ratio [HR],1.41; 95% CI, 0.52-3.89; p = 0.50) or HMII (HR, 0.91; 95% CI, 0.37-2.26; p = 0.84) LVAD. The presence or absence of baseline MR did not influence mortality (HM3 HR, 0.86; 95% CI, 0.56-1.33; p = 0.50; HMII HR, 0.81; 95% CI, 0.54-1.22; p = 0.32), major adverse events or functional capacity. In multivariate analysis, severe baseline MR (p = 0.001), larger left ventricular dimension (p = 0.002), and implantation with the HMII instead of the HM3 LVAD (p = 0.05) were independently associated with an increased likelihood of persistent MR post-implant.

CONCLUSIONS: Hemodynamic unloading after LVAD implantation improves clinically significant MR early, sustainably, and to a greater extent with the HM3 LVAD. Neither baseline nor residual MR influence outcomes after LVAD implantation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты