Algorithm for the analysis of pre-extraction computed tomographic images to evaluate implanted lead-lead interactions and lead-vascular attachments.

Holm Mikayle A, Vatterott Pierce J, Gaasedelen Erik N, Syed Imran, Khan Akbar, Iles Tinen L, Iaizzo Paul A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The number of lead extractions is growing because of the greater population and increasing age of individuals with a cardiac implantable electronic device. Lead extraction procedures can be complex undertakings with risk of significant mortality, and vascular tears in the superior vena cava are of greatest concern.

OBJECTIVE

The purpose of this study was to study whether a novel algorithm that analyzes pre-extraction computed tomographic (CT) images can determine the likelihood and location of lead-lead interactions and lead-vessel attachment within patients' venous vasculatures. This information can be used to identify potential case challenges in the planning stages.

METHODS

We developed an algorithm to estimate the presence and position of lead-lead interactions and lead-vessel adherences by tracking distance between the leads and distance between the lead and superior vena cava in a sample of 12 patients referred to the United Heart and Vascular Clinic for lead extractions due to infection (n = 5), lead failure (n = 5), and tricuspid regurgitation (n = 2).

RESULTS

Preliminary results indicate that the developed algorithm successfully identified lead-lead and lead-vascular attachments compared to review of CT images by medical experts.

CONCLUSION

With future validation and clinical implementation, this algorithm could aid physician preparedness by minimizing intraprocedural emergencies and may improve patient outcomes.

Для цитирования: Holm Mikayle A, Vatterott Pierce J, Gaasedelen Erik N, Syed Imran, Khan Akbar, Iles Tinen L, Iaizzo Paul A. Algorithm for the analysis of pre-extraction computed tomographic images to evaluate implanted lead-lead interactions and lead-vascular attachments.. Heart rhythm. 2020. DOI: 10.1016/j.hrthm.2020.01.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.