MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jamia/ocz159

Медицинская библиотека · Journal of the American Medical Informatics Association : JAMIA · 2019

Automated meal detection from continuous glucose monitor data through simulation and explanation.

Zheng Min, Ni Baohua, Kleinberg Samantha

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Artificial pancreas systems aim to reduce the burden of type 1 diabetes by automating insulin dosing. These systems link a continuous glucose monitor (CGM) and insulin pump with a control algorithm, but require users to announce meals, without which the system can only react to the rise in blood glucose.

OBJECTIVE

We investigate whether CGM data can be used to automatically infer meals in daily life even in the presence of physical activity, which can raise or lower blood glucose.

MATERIALS AND

METHODS

We propose a novel meal detection algorithm that combines simulations with CGM, insulin pump, and heart rate monitor data. When observed and predicted glucose differ, our algorithm uses simulations to test whether a meal may explain this difference. We evaluated our method on simulated data and real-world data from individuals with type 1 diabetes.

RESULTS

In simulated data, we detected meals earlier and with higher accuracy than was found in prior work (25.7 minutes, 1.2 g error; compared with 48.3 minutes, 17.2 g error). In real-world data, we discovered a larger number of plausible meals than was found in prior work (30 meals, 76.7% accepted; compared with 33 meals, 39.4% accepted).

DISCUSSION: Prior research attempted meal detection from CGM, but had delays and lower accuracy in real data or did not allow for physical activity. Our approach can be used to improve insulin dosing in an artificial pancreas and trigger reminders for missed meal boluses.

CONCLUSIONS

We demonstrate that meal information can be robustly inferred from CGM and body-worn sensor data, even in challenging environments of daily life.

Для цитирования: Zheng Min, Ni Baohua, Kleinberg Samantha. Automated meal detection from continuous glucose monitor data through simulation and explanation.. Journal of the American Medical Informatics Association : JAMIA. 2019. DOI: 10.1093/jamia/ocz159.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.