m+Medelevator.RU
← Поиск публикаций
Revista espanola de cardiologia (English ed.) · 2019

Do outcomes following intervention for drug-eluting stent restenosis depend on whether the restenosed stent was polymer-free or polymer-coated?

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Harada Yukinori, Schneider Simon, Colleran Roisin, Rai Himanshu, Bohner Janika, Kuna Constantin, Kufner Sebastian, Giacoppo Daniele, Schüpke Stefanie, Joner Michael, Ibrahim Tareq, Laugwitz Karl-Ludwig, Kastrati Adnan, Byrne Robert A

Аннотация

INTRODUCTION AND OBJECTIVES: Outcomes of patients undergoing percutaneous intervention for drug-eluting stent (DES) restenosis are poorer than those in patients with bare-metal stent restenosis. It is unknown if this is related to the presence of polymer coating. We sought to compare outcomes after interventions for in-stent restenosis (ISR) of polymer-free DES vs durable polymer DES.

METHODS: Patients enrolled in the ISAR-TEST 5 randomized trial who underwent repeat percutaneous intervention for ISR during follow-up were included. Angiographic outcomes at 6 to 8 months and clinical outcomes at 2 years were analyzed and compared between 2 groups according to whether the restenosed stent was a polymer-free or a durable polymer DES. Multivariate analysis was used to adjust for differences between groups.

RESULTS: A total of 326 patients with ISR were included: 220 with ISR in polymer-free DES and 106 with ISR in durable polymer DES. Angiographic follow-up was available for 83.4% of patients. No difference was observed in recurrent binary restenosis between the 2 groups (31.7% vs 27.0%; P=.38; Padjusted=.29). At 2 years, the composite of death, myocardial infarction, or repeat target lesion revascularization were similar between the 2 groups (35.7% vs 34.0%; HR=1.04, 95%CI, 0.70-1.55; P=.83; Padjusted=.79). The rate of repeat target lesion revascularization was also similar in the 2 groups (29.8% vs 31.5%; HR=0.91, 95%CI, 0.60-1.39; P=.68; Padjusted=.62).

CONCLUSIONS: In patients undergoing reintervention for DES-ISR, we found no evidence of differences in outcomes according to whether the restenosed stent was a polymer-free or durable polymer DES.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты