MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000518975

Медицинская библиотека · Ocular oncology and pathology · 2021

Outcomes following Notched Ruthenium-106 Plaque Brachytherapy for Juxtapapillary Choroidal Melanomas.

Sobti Manvi Manu, Edington Magdalena, Connolly Julie, McLernon David J, Schipani Stefano, Ritchie Diana, Cauchi Paul, Chadha Vikas

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This study aimed to evaluate the outcomes of juxtapapillary choroidal melanomas treated with notched ruthenium-106 plaques.

METHODS

Juxtapapillary choroidal melanomas (tumours within 2 disc diameters from the optic disc) treated with notched ruthenium-106 plaques (Eckert & Ziegler, BEBIG, Berlin, Germany) at the Scottish Ocular Oncology Service between 2009 and 2015 were retrospectively reviewed. The data were analysed with respect to various outcome measures including recurrence, complications, vision, and eye preservation.

RESULTS

We reviewed 40 patients with a median tumour diameter of 8.4 mm (range 5-17 mm) and a median thickness of 2.5 mm (range 1.1-6 mm). AJCC tumour category distribution was 62.5% T1, 32.5% T2, and 5% T3 tumours. The mean presenting vision was 0.3 logMAR, and the mean final vision was 0.7 logMAR, with 62.5% retaining >1.0 logMAR and 50% retaining >0.3 logMAR at the final follow-up. The median follow-up was 51 months (14-100 months). Over the maximum follow-up time, 13 tumours (32.5%) recurred. Six of these were treated with salvage proton beam therapy (PBT), 2 with transpupillary thermotherapy followed by PBT, and 5 with enucleation. The final eye retention rate was 87.5%. Complications included maculopathy (10%), retinal detachment (5%), neovascular glaucoma (2.5%), and diplopia (2.5%). The observed risk of recurrence over 5 years was 31% (95% CI: 14.1%, 47.8%), and the risk of enucleation over 5 years was 11.5% (95% CI: 0.9%, 21.8%).

CONCLUSION

Juxtapapillary choroidal melanomas treated with notched ruthenium plaques have a high recurrence rate and frequently need salvage treatment with PBT for tumour control. This has led to a change in our practice toward offering PBT as the first-line treatment for these patients.

Для цитирования: Sobti Manvi Manu, Edington Magdalena, Connolly Julie, McLernon David J, Schipani Stefano, Ritchie Diana, Cauchi Paul, Chadha Vikas. Outcomes following Notched Ruthenium-106 Plaque Brachytherapy for Juxtapapillary Choroidal Melanomas.. Ocular oncology and pathology. 2021. DOI: 10.1159/000518975.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.