MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1352458515579441

Медицинская библиотека · Multiple sclerosis (Houndmills, Basingstoke, England) · 2015

Corticospinal tract integrity measured using transcranial magnetic stimulation and magnetic resonance imaging in neuromyelitis optica and multiple sclerosis.

Manogaran Praveena, Vavasour Irene, Borich Michael, Kolind Shannon H, Lange Alex P, Rauscher Alexander, Boyd Lara, Li David Kb, Traboulsee Anthony

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Both multiple sclerosis (MS) and neuromyelitis optica (NMO) can present with transverse myelitis; however, NMO symptoms are usually more severe and may present with more extensive axonal loss. Transcranial magnetic stimulation (TMS)-based input-output recruitment curves can quantitatively assess the excitability of corticospinal tract pathways and myelin water imaging can quantify the amount of myelin within this same pathway.

OBJECTIVE

To compare differential effects of MS and NMO on TMS recruitment curves and myelin water imaging.

METHODS

Ten healthy controls, 10 individuals with MS and 10 individuals with NMO completed clinical assessments, a TMS assessment and magnetic resonance imaging scan to measure recruitment curves and myelin water fraction in the corticospinal tract.

RESULTS

Individuals with NMO had lower recruitment curve slopes (mean 13.6±6 μV/%) than MS (23.6±11 μV/%) and controls (21.9±9 μV/%, analysis of variance (ANOVA) P=0.05). Corticospinal tract myelin water fraction was lower in individuals with NMO (mean 0.17±0.02) compared to MS (0.19±0.02) and controls (0.20±0.02, ANOVA P=0.0006).

CONCLUSION

Corticospinal pathway damage in individuals with NMO was evident by reduced recruitment curve slope and lower myelin water fraction. These specific measures of corticospinal function and structure may be used to obtain a better understanding and monitor brain injury caused by inflammatory central nervous system disorders.

Для цитирования: Manogaran Praveena, Vavasour Irene, Borich Michael, Kolind Shannon H, Lange Alex P, Rauscher Alexander, Boyd Lara, Li David Kb, Traboulsee Anthony. Corticospinal tract integrity measured using transcranial magnetic stimulation and magnetic resonance imaging in neuromyelitis optica and multiple sclerosis.. Multiple sclerosis (Houndmills, Basingstoke, England). 2015. DOI: 10.1177/1352458515579441.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.