MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jocs.16084

Медицинская библиотека · Journal of cardiac surgery · 2021

Minimally invasive aortic valve repair using geometric ring annuloplasty.

Baker Joshua N, Klokocovnik Tomislav, Miceli Antonio, Glauber Mattia, Wei Lawrence M, Badhwar Vinay, Gerdisch Marc W, Rankin James Scott, Fischlein Theodor J M

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

As aortic valve repair (AVr) for aortic insufficiency (AI) expands, minimally invasive (Mi) approaches are increasingly being applied. Cardiac surgical techniques can be more difficult through small incisions, and this report analyzes medium-term outcomes for MiAVr facilitated by geometric ring annuloplasty.

METHODS

Since 2013, 58 patients were selected for AVr through upper sternotomy third-interspace incisions. The average age was 58.9 ± 15.4 (mean ± SD) years, 71% were male, and preoperative AI grade was 3.6 ± 0.8. Sixty-two percent (36/58) had a proximal aortic replacement for ascending aortic aneurysms (n = 26) and/or remodeling grafts for aortic root aneurysms (n = 10). Annuloplasty rings were placed subannularly (69% trileaflet; 31% bicuspid), and leaflet procedures were performed in 70%. The average ring diameter was 21.6 ± 1.4 mm, and the average aortic clamp time was 113 ± 35 min.

RESULTS

After repair, AI grade fell to an average of 0.5 ± 0.6 (p < .0001), with a mean valve gradient of 12.5 ± 7.1 mmHg. No operative mortalities or major complications occurred. Three patients required reoperations for bleeding, and two had pacemakers. At an average follow-up of 38 months (maximal 88 months), three late deaths and no valve-related complications were observed. Four patients required reoperative aortic valve replacement over follow-up, and Kaplan-Meier survival and freedom from reoperation both exceeded 80% at 88 months. At the last follow-up, the average AI grade was 0.7 ± 0.7, and the mean valve gradient was 12.7 ± 6.3 mmHg.

CONCLUSIONS

Geometric ring annuloplasty was safe and seemed to facilitate performing AVr ± proximal aortic replacement through Mi incisions. Hemodynamic improvements were significant, medium-term clinical outcomes were acceptable, and results could improve further with experience.

Для цитирования: Baker Joshua N, Klokocovnik Tomislav, Miceli Antonio, Glauber Mattia, Wei Lawrence M, Badhwar Vinay, Gerdisch Marc W, Rankin James Scott, Fischlein Theodor J M. Minimally invasive aortic valve repair using geometric ring annuloplasty.. Journal of cardiac surgery. 2021. DOI: 10.1111/jocs.16084.