Importance of through-plane heart motion correction for the assessment of aortic regurgitation severity using phase contrast magnetic resonance imaging.

Lagerstrand Kerstin M, Truedsson Frida, Gao Sinsia A, Johansson Alexander, Bech-Hanssen Odd, Polte Christian L, Johnsson Åse A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To elucidate the influence of through-plane heart motion on the assessment of aortic regurgitation (AR) severity using phase contrast magnetic resonance imaging (PC-MRI).

APPROACH: A patient cohort with chronic AR (n = 34) was examined with PC-MRI. The regurgitant volume (RVol) and fraction (RFrac) were extracted from the PC-MRI data before and after through-plane heart motion correction and was then used for assessment of AR severity.

RESULTS

The flow volume errors were strongly correlated to aortic diameter (R = 0.80, p < 0.001) with median (IQR 25%;75%): 16 (14; 17) ml for diameter>40mm, compared with 9 (7; 10) ml for normal aortic size (p < 0.001). RVol and RFrac were underestimated (uncorrected:64 ± 37 ml and 39 ± 17%; corrected:76 ± 37 ml and 44 ± 15%; p < 0.001) and ~ 20% of the patients received lower severity grade without correction.

CONCLUSION

Through-plane heart motion introduces relevant flow volume errors, especially in patients with aortic dilatation that may result in underestimation of the severity grade in patients with chronic AR.

Для цитирования: Lagerstrand Kerstin M, Truedsson Frida, Gao Sinsia A, Johansson Alexander, Bech-Hanssen Odd, Polte Christian L, Johnsson Åse A. Importance of through-plane heart motion correction for the assessment of aortic regurgitation severity using phase contrast magnetic resonance imaging.. Magnetic resonance imaging. 2021. DOI: 10.1016/j.mri.2021.09.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.