Journal of cardiac surgery · 2021
A new technique that prevents paravalvular leakage after aortic valve replacement using a rapid-deployment valve system.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yamamoto Taira, Endo Daisuke, Yamaoka Hironobu, Matsushita Satoshi, Kajimoto Kan, Asai Tohru, Amano Atsushi
Аннотация
BACKGROUND: We report our 1-year single-center experience of a new technique of aortic valve replacement using a rapid-deployment valve (RD-AVR) to avoid postoperative complications. We also report the unexpected pitfalls and handling techniques that we have seen in past cases.
METHODS: We performed aortic valve replacement on 38 patients between May 2019 and April 2020. Their mean age was 74 years. The primary outcomes were in-hospital mortality and short-term results during a 1-year follow-up period, while the secondary outcomes were related to prosthetic valve function, especially paravalvular leakage (PVL). We further analyzed the relationship between the new technique and its outcomes.
RESULTS: The mean operative time was 196 min. There were no in-hospital deaths, and the mean duration of postoperative hospital stay was 11.8 days. Valvular measurements using three-dimensional computed tomography were larger and more accurate than those measured using ultrasonic echocardiography. Postoperative RD-AVR prosthetic valve function was excellent. However, PVL occurred in four cases 1 week and 1 year postoperatively and regurgitation did not improve. A gap associated with PVL was identified below the right-noncoronary commissure. To prevent PVL, we additionally stitched this gap in the later 18 cases; there was no case of PVL and no new pacemaker implantation in these cases.
CONCLUSIONS: PVL is more likely to occur if there is a gap below the R-N commissure, especially in cases with a large annulus; therefore, applying an additional stitch to the R-N commissure is extremely useful.
METHODS: We performed aortic valve replacement on 38 patients between May 2019 and April 2020. Their mean age was 74 years. The primary outcomes were in-hospital mortality and short-term results during a 1-year follow-up period, while the secondary outcomes were related to prosthetic valve function, especially paravalvular leakage (PVL). We further analyzed the relationship between the new technique and its outcomes.
RESULTS: The mean operative time was 196 min. There were no in-hospital deaths, and the mean duration of postoperative hospital stay was 11.8 days. Valvular measurements using three-dimensional computed tomography were larger and more accurate than those measured using ultrasonic echocardiography. Postoperative RD-AVR prosthetic valve function was excellent. However, PVL occurred in four cases 1 week and 1 year postoperatively and regurgitation did not improve. A gap associated with PVL was identified below the right-noncoronary commissure. To prevent PVL, we additionally stitched this gap in the later 18 cases; there was no case of PVL and no new pacemaker implantation in these cases.