DOI 10.1016/j.amjcard.2020.12.047

Медицинская библиотека · The American journal of cardiology · 2020

Transcatheter Aortic Valve Implantation for Failed Surgical Aortic Bioprostheses Using a Self-Expanding Device (from the Prospective VIVA Post Market Study).

Kornowski Ran, Chevalier Bernard, Verhoye Jean-Philippe, Holzhey David, Harnath Axel, Schӓfer Ulrich, Teiger Emmanuel, Manigold Thibaut, Modine Thomas, Souteyrand Geraud, Champagnac Didier, Oh Jae K, Li Shuzhen, Tchétché Didier, VIVA Investigators

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Patients with symptomatic aortic stenosis are often treated with a surgical valve replacement. Surgical bioprosthetic valves degenerate over time and therefore may necessitate a redo surgery. This analysis reports the 2-year clinical outcomes of the Valve-in-Valve study, which evaluated transcatheter aortic valve implantation using the CoreValve and Evolut R devices in patients with degenerated surgical aortic bioprostheses at high risk for surgery. The prospective Valve-in-Valve study enrolled 202 eligible patients with failing surgical aortic bioprostheses due to stenosis, regurgitation, or a combination of both. The Evolut R bioprosthesis was used in 90.5% of valve-in-valve transcatheter aortic valve implantation cases. Two-year all-cause and cardiovascular mortality rates were 16.5% and 11.1%, respectively. Other clinical events included stroke (7.9%), disabling stroke (1.7%), and new pacemaker implantation (10.1%). The 2-year all-cause mortality rate was significantly higher in patients with discharge mean gradients ≥20 mmHg vs. those with lower mean gradients (21.0% vs 7.6%, p = 0.025). Discharge mean gradients ≥20 mm Hg were associated with smaller surgical bioprostheses (OR, 7.2 [95% CI 2.3 to 22.1]. In patients with failing surgical aortic bioprostheses, valve-in-valve treatment using a supra-annular self-expanding bioprosthesis provides significant functional improvements with acceptable rates of complications, especially if a postprocedural mean gradient of <20 mmHg can be achieved.

Для цитирования: Kornowski Ran, Chevalier Bernard, Verhoye Jean-Philippe, Holzhey David, Harnath Axel, Schӓfer Ulrich, Teiger Emmanuel, Manigold Thibaut, Modine Thomas, Souteyrand Geraud, Champagnac Didier, Oh Jae K, Li Shuzhen, Tchétché Didier, VIVA Investigators. Transcatheter Aortic Valve Implantation for Failed Surgical Aortic Bioprostheses Using a Self-Expanding Device (from the Prospective VIVA Post Market Study).. The American journal of cardiology. 2020. DOI: 10.1016/j.amjcard.2020.12.047.