MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/openhrt-2020-001391

Медицинская библиотека · Open heart · 2020

Predictors of paravalvular leak following implantation of the ACURATE neo transcatheter heart valve: the PREDICT PVL study.

Brinkert Miriam, De Boeck Bart, Stämpfli Simon F, Wolfrum Mathias, Moccetti Federico, Attinger-Toller Adrian, Bossard Matthias, Cuculi Florim, Kobza Richard, Toggweiler Stefan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Report predictors and the natural course of paravalvular leak (PVL) following implantation of the ACURATE neo transcatheter heart valve (THV).

BACKGROUND

Understanding the mechanisms of PVL may help to improve patient selection, patient outcomes and the design of next-generation THVs.

METHODS

A total of 30 patients (mean age 81±5 years, 47% women) undergoing transcatheter aortic valve replacement with the ACURATE neo were enrolled in the PREDICT PVL study. The effective regurgitant orifice area (EROA, in mm2) of PVL was assessed by transthoracic and transoesophageal echocardiography before discharge and at 6 months follow-up.

RESULTS

PVL was none/trace in 10 (33%), mild in 18 (60%) and moderate in 2 (7%) patients and occurred in distinct locations with largest EROAs in the area of the left coronary cusp and its adjacent commissures. Independent predictors for EROA were implantation depth (r coefficient -1.9 mm2 per mm implantation depth, p=0.01), leaflet calcification (6.2 mm2 per calcification grade, p=0.03) and THV size L (7.6 mm2 more than size S or M, p=0.01). At 6 months follow-up, EROA decreased by 29% from 13.7±9.7 mm2 to 9.5±7.9 mm2 (p<0.01). Patients with smaller EROAs were more likely to be in New York Heart Association class 1 than patients with larger EROAs (p<0.01).

CONCLUSIONS

PVL occurred predominantly in the region of the left coronary cusp and decreased by 29% during 6 months of follow-up. Our results underscore the importance of adequate patient selection and optimal implantation depth.

Для цитирования: Brinkert Miriam, De Boeck Bart, Stämpfli Simon F, Wolfrum Mathias, Moccetti Federico, Attinger-Toller Adrian, Bossard Matthias, Cuculi Florim, Kobza Richard, Toggweiler Stefan. Predictors of paravalvular leak following implantation of the ACURATE neo transcatheter heart valve: the PREDICT PVL study.. Open heart. 2020. DOI: 10.1136/openhrt-2020-001391.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.