European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2021
Leaflet kinematics after the Yacoub and Florida-sleeve operations: results of an in vitro study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Tasca Giordano, Jaworek Michal, Lucherini Federico, Trinca Francesco, Redaelli Paola, Antona Carlo, Vismara Riccardo
Аннотация
OBJECTIVES: The Florida-sleeve is a valve-sparing technique that causes minimal interference to leaflet kinematics and aortic root dynamism. The aim of this in vitro study was to evaluate the effects of the Florida-sleeve and Yacoub techniques on aortic leaflet kinematics.
METHODS: Two groups of 6 whole porcine hearts were treated with either the Florida-sleeve technique or the Yacoub technique and tested in a pulsatile loop. Valve fluid dynamics, coronary flow analysis and valve echocardiograms were performed both before and after the procedures.
RESULTS: Both procedures showed no difference in rapid valve opening time as compared with their respective baseline values. The Florida-sleeve procedure showed a shorter slow closing time (192 ± 19 ms vs baseline 244 ± 14 ms, P = 0.016) and increased slow closing velocity (-1.5 ± 0.4 cm/s vs baseline -0.8 ± 0.4 cm/s, P = 0.038). In the rapid valve closing phase, the Yacoub procedure showed a trend towards slower closing valve velocity (-16 ± 9 cm/s vs baseline -25 ± 9 cm/s, P = 0.07). The Yacoub procedure showed larger leaflet displacement at the end of the slow valve closing time that was 2.0 ± 0.5 cm vs baseline 1.5 ± 0.3 cm, P = 0.044. When comparing the Florida-sleeve and Yacoub procedures, the former showed statistically significant shorter slow valve closing time (P = 0.017).
CONCLUSIONS: This study showed that the Florida-sleeve technique alters the slow closing phase of the aortic valve leaflet kinematics when compared with both the normal baseline and Yacoub procedure, while the latter showed a larger leaflet displacement before the rapid closing valve phase.
METHODS: Two groups of 6 whole porcine hearts were treated with either the Florida-sleeve technique or the Yacoub technique and tested in a pulsatile loop. Valve fluid dynamics, coronary flow analysis and valve echocardiograms were performed both before and after the procedures.
RESULTS: Both procedures showed no difference in rapid valve opening time as compared with their respective baseline values. The Florida-sleeve procedure showed a shorter slow closing time (192 ± 19 ms vs baseline 244 ± 14 ms, P = 0.016) and increased slow closing velocity (-1.5 ± 0.4 cm/s vs baseline -0.8 ± 0.4 cm/s, P = 0.038). In the rapid valve closing phase, the Yacoub procedure showed a trend towards slower closing valve velocity (-16 ± 9 cm/s vs baseline -25 ± 9 cm/s, P = 0.07). The Yacoub procedure showed larger leaflet displacement at the end of the slow valve closing time that was 2.0 ± 0.5 cm vs baseline 1.5 ± 0.3 cm, P = 0.044. When comparing the Florida-sleeve and Yacoub procedures, the former showed statistically significant shorter slow valve closing time (P = 0.017).
CONCLUSIONS: This study showed that the Florida-sleeve technique alters the slow closing phase of the aortic valve leaflet kinematics when compared with both the normal baseline and Yacoub procedure, while the latter showed a larger leaflet displacement before the rapid closing valve phase.