m+Medelevator.RU
← Поиск публикаций
Cardiovascular revascularization medicine : including molecular interventions · 2014

Direct transcatheter aortic valve implantation with self-expandable bioprosthesis: feasibility and safety.

Сравнительное исследованиеОценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fiorina Claudia, Maffeo Diego, Curello Salvatore, Lipartiti Felicia, Chizzola Giuliano, D'Aloia Antonio, Adamo Marianna, Mastropierro Rosy, Gavazzi Emanuele, Ciccarese Camilla, Chiari Ermanna, Ettori Federica

Аннотация

BACKGROUND: Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve.

MATERIAL AND METHODS: Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI.

RESULTS: High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85%vs.64%,p=0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL≥2;9%vs.33%,p=0.02). Safety combined end point at 30 days was similar in both groups.

CONCLUSION: Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты