The Annals of thoracic surgery · 2013
Transvalvular pacemaker leads increase the recurrence of regurgitation after tricuspid valve repair.
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mazine Amine, Bouchard Denis, Moss Emmanuel, Marquis-Gravel Guillaume, Perrault Louis P, Demers Philippe, Carrier Michel, Cartier Raymond, Pellerin Michel
Аннотация
BACKGROUND: The impact of a transvalvular pacemaker lead on the progression of tricuspid regurgitation (TR) after tricuspid valve (TV) repair has not been clearly demonstrated. The aim of this study was to evaluate the presence of a transvalvular pacemaker lead as a risk factor for TR after TV repair in a large patient cohort.
METHODS: A retrospective review included 791 patients who underwent TV repair at our institution from 1977 to 2008. All patients bearing a transvenous pacemaker implanted either preoperatively or within 30 days of surgery were categorized in the "PACE" group (n=176), the remaining patients were categorized in the "NO PACE" group (n=615).
RESULTS: Mean age was 61±11 years, and 575 patients (73%) were female. Mean follow-up was 5.8±5.5 years. Operative mortality was 13%. At discharge, TR severity was 3+ or greater in 10% and 15% of patients in the PACE and NO PACE groups, respectively (p=0.19). Multivariate analysis using a Cox regression model identified the presence of a transvenous pacemaker as an independent risk factor for recurrence of TR 2+ or greater (hazard ratio [HR] 1.60, p=0.008) and TR 3+ or greater (HR 1.47, p=0.046) at last follow-up. The presence of a transvenous pacemaker was also a significant independent predictor of late mortality (HR 2.12, p=0.02).
CONCLUSIONS: In patients undergoing tricuspid valve surgery, the presence of a transvenous pacemaker implanted either preoperatively or within 30 days of surgery is associated with a significantly increased risk of persistent or recurrent TR at late follow-up.
METHODS: A retrospective review included 791 patients who underwent TV repair at our institution from 1977 to 2008. All patients bearing a transvenous pacemaker implanted either preoperatively or within 30 days of surgery were categorized in the "PACE" group (n=176), the remaining patients were categorized in the "NO PACE" group (n=615).
RESULTS: Mean age was 61±11 years, and 575 patients (73%) were female. Mean follow-up was 5.8±5.5 years. Operative mortality was 13%. At discharge, TR severity was 3+ or greater in 10% and 15% of patients in the PACE and NO PACE groups, respectively (p=0.19). Multivariate analysis using a Cox regression model identified the presence of a transvenous pacemaker as an independent risk factor for recurrence of TR 2+ or greater (hazard ratio [HR] 1.60, p=0.008) and TR 3+ or greater (HR 1.47, p=0.046) at last follow-up. The presence of a transvenous pacemaker was also a significant independent predictor of late mortality (HR 2.12, p=0.02).
CONCLUSIONS: In patients undergoing tricuspid valve surgery, the presence of a transvenous pacemaker implanted either preoperatively or within 30 days of surgery is associated with a significantly increased risk of persistent or recurrent TR at late follow-up.
Предметные рубрики MeSH
AgedCohort StudiesFemaleFollow-Up StudiesHeart Valve Prosthesis ImplantationHospital MortalityHumansMaleMiddle AgedMultivariate AnalysisPacemaker, ArtificialPostoperative ComplicationsPreoperative CareProportional Hazards ModelsRecurrenceRetrospective StudiesRisk AssessmentSurvival RateTreatment OutcomeTricuspid ValveTricuspid Valve InsufficiencyUltrasonography