Pitfalls in interpreting bioprosthetic aortic valve pressure gradients: a cautionary tale!

Buchholz Stefan, Robaei Daniel, Jacobs Neil H, Feneley Michael P

СтатьяПеревод пока не подготовлен

Аннотация

High transvalvular pressure gradients following aortic valve replacement can be caused by several possible mechanisms. We present the case of an elderly woman with an elevated pressure gradient across an aortic valve bioprosthesis in the setting of complete heart block. After consideration of the presence of complete heart block, the hemodynamic profile of the specific prosthesis, and patient-prosthesis mismatch, only a mild degree of stenosis was found to be attributable to degeneration of the prosthesis. There is no literature quantifying the hemodynamic effect of complete heart block on the pressure gradients across bioprosthetic aortic valves. In the case presented, the transvalvular peak and mean pressure gradients were reduced by 41% and 39%, respectively, following treatment of complete heart block by insertion of a permanent pacemaker.

Для цитирования: Buchholz Stefan, Robaei Daniel, Jacobs Neil H, Feneley Michael P. Pitfalls in interpreting bioprosthetic aortic valve pressure gradients: a cautionary tale!. Echocardiography (Mount Kisco, N.Y.). 2012. DOI: 10.1111/j.1540-8175.2012.01775.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.