MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2011.09.013

Медицинская библиотека · JACC. Cardiovascular interventions · 2012

Percutaneous edge-to-edge mitral valve repair in high-surgical-risk patients: do we hit the target?

Van den Branden Ben J L, Swaans Martin J, Post Martijn C, Rensing Benno J W M, Eefting Frank D, Jaarsma Wybren, Van der Heyden Jan A S

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to assess the feasibility and safety of percutaneous edge-to-edge mitral valve (MV) repair in patients with an unacceptably high operative risk.

BACKGROUND

MV repair for mitral regurgitation (MR) can be accomplished by use of a clip that approximates the free edges of the mitral leaflets.

METHODS

All patients were declined for surgery because of a high logistic EuroSCORE (>20%) or the presence of other specific surgical risk factors. Transthoracic echocardiography was performed before and 6 months after the procedure. Differences in New York Heart Association (NYHA) functional class, quality of life (QoL) using the Minnesota questionnaire, and 6-min walk test (6-MWT) distances were reported.

RESULTS

Fifty-five procedures were performed in 52 patients (69.2% male, age 73.2 ± 10.1 years, logistic EuroSCORE 27.1 ± 17.0%). In 3 patients, partial clip detachment occurred; a second clip was placed successfully. One patient experienced cardiac tamponade. Two patients developed inguinal bleeding, of whom 1 needed surgery. Six patients (11.5%) died during 6-month follow-up (5 patients as a result of progressive heart failure and 1 noncardiac death). The MR grade before repair was ≥3 in 100%; after 6 months, a reduction in MR grade to ≤2 was present in 79% of the patients. Left ventricular (LV) end-diastolic diameter, LV ejection fraction, and systolic pulmonary artery pressure improved significantly. Accompanied improvements in NYHA functional class, QoL index, 6-MWT distances, and log N-terminal pro-B-type natriuretic peptide were observed.

CONCLUSIONS

In a high-risk population, MR reduction can be achieved by percutaneous edge-to-edge valve repair, resulting in LV remodeling with improvement of functional capacity after 6 months.

Для цитирования: Van den Branden Ben J L, Swaans Martin J, Post Martijn C, Rensing Benno J W M, Eefting Frank D, Jaarsma Wybren, Van der Heyden Jan A S. Percutaneous edge-to-edge mitral valve repair in high-surgical-risk patients: do we hit the target?. JACC. Cardiovascular interventions. 2012. DOI: 10.1016/j.jcin.2011.09.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление