Frequency of conduction disturbances after transcatheter implantation of an Edwards Sapien aortic valve prosthesis.

Godin Matthieu, Eltchaninoff Helene, Furuta Akira, Tron Christophe, Anselme Frederic, Bejar Karim, Sanchez-Giron Carlos, Bauer Fabrice, Litzler Pierre-Yves, Bessou Jean-Paul, Cribier Alain

СтатьяПеревод пока не подготовлен

Аннотация

We evaluated the incidence of conduction abnormalities and requirement for permanent pacemaker in patients undergoing transcatheter aortic valve implantation (TAVI) with the Edwards Sapien prosthesis. In 2009, >8,000 patients were treated with TAVI using 1 of the 2 commercialized models of bioprosthesis (Edwards Sapien, Edwards Lifesciences, Irvine, California; and CoreValve, Medtronic, Irvine, California). Occurrence of conduction abnormalities including complete atrioventricular block requiring permanent pacemaker has been reported after TAVI with the 2 models of valve, more frequently with the CoreValve. We analyzed standard 12-lead electrocardiograms of 69 consecutive patients in whom an Edwards Sapien prosthesis was successfully implanted. Electrocardiograms were examined before treatment, at day 1, and at 1-month follow-up. Heart rate, PR and QT intervals and QRS duration were measured and the presence of a first-, second-, or third-degree atrioventricular block was documented. There was a slight increase in heart rate and a discrete decrease in QT interval at day 1. These values had returned to baseline values at 1 month. There was no change in PR interval but a transitory increase in QRS duration was noted. Frequency of left bundle branch block increased from 14.5% at baseline to 27.5% at day 1 with a decreased incidence at day 30 (21.3%). Permanent pacemaker was required in only 3 patients (4.3%). In conclusion, in our experience, conductive disorders and requirement of a definitive pacemaker after implantation of an Edwards Sapien aortic bioprosthesis are infrequent. The physical properties of this prosthesis may explain this observation.

Для цитирования: Godin Matthieu, Eltchaninoff Helene, Furuta Akira, Tron Christophe, Anselme Frederic, Bejar Karim, Sanchez-Giron Carlos, Bauer Fabrice, Litzler Pierre-Yves, Bessou Jean-Paul, Cribier Alain. Frequency of conduction disturbances after transcatheter implantation of an Edwards Sapien aortic valve prosthesis.. The American journal of cardiology. 2010. DOI: 10.1016/j.amjcard.2010.04.029.

Предметные рубрики MeSH