Barra Sérgio, Duehmke Rudolf, Providência Rui, Narayanan Kumar, Reitan Christian, Roubicek Tomas, Polasek Rostislav, Chow Antony, Defaye Pascal, Fauchier Laurent, Piot Olivier, Deharo Jean-Claude, Sadoul Nicolas, Klug Didier, Garcia Rodrigue, Dockrill Seth, Virdee Munmohan, Pettit Stephen, Agarwal Sharad, Borgquist Rasmus, Marijon Eloi, Boveda Serge

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

AIMS: The very long-term outcome of patients who survive the first few years after receiving cardiac resynchronization therapy (CRT) has not been well described thus far. We aimed to provide long-term outcomes, especially with regard to the occurrence of sudden cardiac death (SCD), in CRT patients without (CRT-P) and with defibrillator (CRT-D).

METHODS AND

RESULTS

A total of 1775 patients, with ischaemic or non-ischaemic dilated cardiomyopathy, who were alive 5 years after CRT implantation, were enrolled in this multicentre European observational cohort study. Overall long-term mortality rates and specific causes of death were assessed, with a focus on late SCD. Over a mean follow-up of 30 months (interquartile range 10-42 months) beyond the first 5 years, we observed 473 deaths. The annual age-standardized mortality rates of CRT-D and CRT-P patients were 40.4 [95% confidence interval (CI) 35.3-45.5] and 97.2 (95% CI 85.5-109.9) per 1000 patient-years, respectively. The adjusted hazard ratio (HR) for all-cause mortality was 0.99 (95% CI 0.79-1.22). Twenty-nine patients in total died of late SCD (14 with CRT-P, 15 with CRT-D), corresponding to 6.1% of all causes of death in both device groups. Specific annual SCD rates were 8.5 and 5.8 per 1000 patient-years in CRT-P and CRT-D patients, respectively, with no significant difference between groups (adjusted HR 1.0, 95% CI 0.45-2.44). Death due to progressive heart failure represented the principal cause of death (42.8% in CRT-P patients and 52.6% among CRT-D recipients), whereas approximately one-third of deaths in both device groups were due to non-cardiovascular death.

CONCLUSION

In this first description of very long-term outcomes among CRT recipients, progressive heart failure death still represented the most frequent cause of death in patients surviving the first 5 years after CRT implant. In contrast, SCD represents a very low proportion of late mortality irrespective of the presence of a defibrillator.

Для цитирования: Barra Sérgio, Duehmke Rudolf, Providência Rui, Narayanan Kumar, Reitan Christian, Roubicek Tomas, Polasek Rostislav, Chow Antony, Defaye Pascal, Fauchier Laurent, Piot Olivier, Deharo Jean-Claude, Sadoul Nicolas, Klug Didier, Garcia Rodrigue, Dockrill Seth, Virdee Munmohan, Pettit Stephen, Agarwal Sharad, Borgquist Rasmus, Marijon Eloi, Boveda Serge. Very long-term survival and late sudden cardiac death in cardiac resynchronization therapy patients.. European heart journal. 2019. DOI: 10.1093/eurheartj/ehz238.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.