m+Medelevator.RU
← Поиск публикаций
Heart rhythm · 2018

Use and outcomes of subcutaneous implantable cardioverter-defibrillator (ICD) after transvenous ICD extraction: An analysis of current clinical practice and a comparison with transvenous ICD reimplantation.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Viani Stefano, Migliore Federico, Tola Gianfranco, Pisanò Ennio C L, Russo Antonio Dello, Luzzi Giovanni, Sartori Paolo, Piro Agostino, Rordorf Roberto, Forleo Giovanni Battista, Rago Anna, Segreti Luca, Bertaglia Emanuele, Biffi Mauro, Lovecchio Mariolina, Valsecchi Sergio, Diemberger Igor, Bongiorni Maria Grazia

Аннотация

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) does not require the insertion of any leads into the cardiovascular system.

OBJECTIVE: The aims of the study were to describe current practice and to measure outcomes associated with S-ICD or standard single-chamber transvenous ICD (TV-ICD) use after TV-ICD explantation.

METHODS: We analyzed all consecutive patients who underwent transvenous extraction of an ICD and subsequent implantation of an S-ICD or a single-chamber TV-ICD at 12 Italian centers from 2011 to 2017.

RESULTS: A total of 229 patients were extracted and subsequently reimplanted with an S-ICD (90; 39%) or a single-chamber TV-ICD (139; 61%). S-ICD implantation increased from 9% in 2011 to 85% in 2017 (P < .001). Patients reimplanted with an S-ICD were younger (53 ± 13 years vs 60 ± 18 years; P = .011) and more frequently had undergone extraction owing to infection (73% vs 52%; P < .001). The rates of complications at follow-up were comparable between groups (hazard ratio 0.97; 95% confidence interval 0.49-1.92; P = .940). No lead failures, systemic infections, or system-related deaths occurred in the S-ICD group. In the TV-ICD group, 1 lead fracture occurred and 2 systemic infections were reported, resulting in death in 1 case. In the S-ICD group, the rate of complications was lower when the generator was positioned in a sub- or intermuscular pocket (hazard ratio 0.21; 95% confidence interval 0.05-0.87; P = .048).

CONCLUSION: Our results show an increasing use of S-ICD over the years in patients undergoing TV-ICD explantation. An S-ICD is preferably adopted in young patients, mostly in the case of infection. The complication rate was comparable between groups and decreased when a sub- or intermuscular S-ICD generator position was adopted.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты