MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2018.06.046

Медицинская библиотека · Heart rhythm · 2018

Implantable cardioverter-defibrillator use in catecholaminergic polymorphic ventricular tachycardia: A systematic review.

Roston Thomas M, Jones Karolina, Hawkins Nathaniel M, Bos J Martijn, Schwartz Peter J, Perry Frances, Ackerman Michael J, Laksman Zachary W M, Kaul Padma, Lieve Krystien V V, Atallah Joseph, Krahn Andrew D, Sanatani Shubhayan

СтатьяПоддержка исследования: вне правительства СШАСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

The implantable cardioverter-defibrillator (ICD) may be associated with a high risk of complications in patients with catecholaminergic polymorphic ventricular tachycardia (CPVT). However, ICDs in this population have not been systematically evaluated.

OBJECTIVE

The purpose of this study was to characterize the use and outcomes of ICDs in CPVT.

METHODS

We conducted a systematic review using Embase, MEDLINE, PubMed, and Google Scholar to identify studies that included patients with CPVT who had an ICD.

RESULTS

Fifty-three studies describing 1429 patients with CPVT were included. In total, 503 patients (35.2%) had an ICD (median age 15.0 years; interquartile range 11.0-21.0 years). Among ICD recipients with a reported medication status, 96.7% were prescribed β-blockers and 13.2% flecainide. Sympathetic denervation was performed in 23.2%. Nearly half of patients received an ICD for primary prevention (47.3%), and 12.8% were prescribed optimal antiarrhythmic therapy. During follow-up, 40.1% had ≥1 appropriate shock, 20.8% experienced ≥1 inappropriate shock, 19.6% had electrical storm, and 7 patients (1.4%) died. An ICD-associated electrical storm was implicated in 4 deaths. Additional complications such as lead failure, endocarditis, or surgical revisions were observed in 96 of 296 patients (32.4%). A subanalysis of the 10 studies encompassing 330 patients with the most detailed ICD-related data showed similar trends.

CONCLUSION

In this population with CPVT, ICDs were common and associated with a high burden of shocks and complications. The reliance on primary prevention ICDs, and poor uptake of adjuvant antiarrhythmic therapies, suggests that improved adherence to guideline-directed management could reduce ICD use and harm.

Для цитирования: Roston Thomas M, Jones Karolina, Hawkins Nathaniel M, Bos J Martijn, Schwartz Peter J, Perry Frances, Ackerman Michael J, Laksman Zachary W M, Kaul Padma, Lieve Krystien V V, Atallah Joseph, Krahn Andrew D, Sanatani Shubhayan. Implantable cardioverter-defibrillator use in catecholaminergic polymorphic ventricular tachycardia: A systematic review.. Heart rhythm. 2018. DOI: 10.1016/j.hrthm.2018.06.046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.