MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.218.2.r01fe33491

Медицинская библиотека · Radiology · 2001

Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors?

Ko J P, Shepard J O, Drucker E A, Aquino S L, Sharma A, Sabloff B, Halpern E, McLoud T C

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To study factors that may influence pneumothorax and chest tube placement rate, especially needle dwell time and pleural puncture angle.

MATERIALS AND

METHODS

In 159 patients, 160 coaxial computed tomography (CT)-guided lung biopsies were performed. Dwell time, the time between pleural puncture and needle removal, was calculated. The smallest angle of the needle with the pleura ("needle-pleural angle") was measured. These and other variables were correlated with pneumothorax and chest tube rates.

RESULTS

One hundred fifty biopsies were included. There were 58 (39%) pneumothoraces (14 noted only at CT), with eight (5%) biopsies resulting in chest tube placement. Longer dwell times (mean, 29 minutes; range, 12-66 minutes) did not correlate with pneumothoraces (P =.81). Smaller needle-pleural angles (< 80 degrees) [corrected], decreased forced expiratory volume in 1 second to vital capacity ratio (<50%), lateral pleural puncture, and lesions along fissures were associated with higher [corrected] pneumothorax rates (P <.05). Emphysema along the needle path, pulmonary function tests showing ventilatory obstruction, and lesions along fissures predisposed patients to chest tube placement (P <.05). Pleural thickening and prior surgery were associated with lower pneumothorax rates (P <.05).

CONCLUSION

Longer dwell times do not correlate with pneumothorax and should not influence the decision to obtain more biopsy samples. A shallow pleural puncture angle may increase the pneumothorax rate.

Для цитирования: Ko J P, Shepard J O, Drucker E A, Aquino S L, Sharma A, Sabloff B, Halpern E, McLoud T C. Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors?. Radiology. 2001. DOI: 10.1148/radiology.218.2.r01fe33491.