DOI 10.5603/cj.a2019.0088

Медицинская библиотека · Cardiology journal · 2019

Predictors of pacing-dependency in patients with cardiovascular implantable electronic devices.

Grimm Wolfram, Grimm Kathrin, Greene Brandon, Parahuleva Mariana

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Data on the prevalence and predictors for the development of pacing-dependency in patients with cardiovascular implantable electronic devices (CIEDs) are sparse.

METHODS

Pacing-dependency defined as an absence of intrinsic rhythm of ≥ 30 bpm was determined in 802 consecutive patients with CIEDs who visited the documented pacemaker or implantable cardioverter- defibrillator outpatient clinic for routine follow-up.

RESULTS

A total of 131 (16%) patients were found to be pacing-dependent 67 ± 70 months after CIED implant. Multivariate analysis revealed a significant association between pacing-dependency and the following clinical variables: second or third-degree atrioventricular (AV) block at implant (OR = 19.9; 95% CI: 10.9-38.5, p < 0.01), atrial fibrillation at implant (OR = 2.15; 95% CI: 1.16-4.05, p = 0.02), left ventricular ejection fraction (LVEF) ≤ 30% (OR = 2.06; 95% CI: 1.03-4.15, p = 0.04), B-type natriuretic peptide (BNP) > 150 pg/mL (OR = 2.12; 95% CI: 1.16-3.97, p = 0.02), chronic kidney disease (OR = 1.86; 95% CI: 1.08-3.26, p = 0.03), and follow-up duration after implantation > 5 years (OR = 3.29; 95% CI: 1.96-5.64, p < 0.01). None of the remaining clinical variables including age, gender, diabetes mellitus, underlying heart disease, prior cardiac surgery or medication during follow-up including betablockers and amiodarone predicted pacing-dependency.

CONCLUSIONS

Pacing-dependency is associated with second or third-degree AV-block at implant, atrial fibrillation before implant, low LVEF, elevated BNP, chronic kidney disease and follow-up duration after implant.

Для цитирования: Grimm Wolfram, Grimm Kathrin, Greene Brandon, Parahuleva Mariana. Predictors of pacing-dependency in patients with cardiovascular implantable electronic devices.. Cardiology journal. 2019. DOI: 10.5603/cj.a2019.0088.