MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1164/rccm.201806-1111oc

Медицинская библиотека · American journal of respiratory and critical care medicine · 2019

Intrathoracic Airway Closure Impacts CO2 Signal and Delivered Ventilation during Cardiopulmonary Resuscitation.

Grieco Domenico L, J Brochard Laurent, Drouet Adrien, Telias Irene, Delisle Stéphane, Bronchti Gilles, Ricard Cecile, Rigollot Marceau, Badat Bilal, Ouellet Paul, Charbonney Emmanuel, Mancebo Jordi, Mercat Alain, Savary Dominique, Richard Jean-Christophe M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

RATIONALE: End-tidal CO2 (EtCO2) is used to monitor cardiopulmonary resuscitation (CPR), but it can be affected by intrathoracic airway closure. Chest compressions induce oscillations in expired CO2, and this could reflect variable degrees of airway patency.

OBJECTIVES

To understand the impact of airway closure during CPR, and the relationship between the capnogram shape, airway closure, and delivered ventilation.

METHODS

This study had three parts: 1) a clinical study analyzing capnograms after intubation in patients with out-of-hospital cardiac arrest receiving continuous chest compressions, 2) a bench model, and 3) experiments with human cadavers. For 2 and 3, a constant CO2 flow was added in the lung to simulate CO2 production. Capnograms similar to clinical recordings were obtained and different ventilator settings tested. EtCO2 was compared with alveolar CO2 (bench). An airway opening index was used to quantify chest compression-induced expired CO2 oscillations in all three clinical and experimental settings.

MEASUREMENTS AND MAIN

RESULTS

A total of 89 patients were analyzed (mean age, 69 ± 15 yr; 23% female; 12% of hospital admission survival): capnograms exhibited various degrees of oscillations, quantified by the opening index. CO2 value varied considerably across oscillations related to consecutive chest compressions. In bench and cadavers, similar capnograms were reproduced with different degrees of airway closure. Differences in airway patency were associated with huge changes in delivered ventilation. The opening index and delivered ventilation increased with positive end-expiratory pressure, without affecting intrathoracic pressure. Maximal EtCO2 recorded between ventilator breaths reflected alveolar CO2 (bench).

CONCLUSIONS

During chest compressions, intrathoracic airway patency greatly affects the delivered ventilation. The expired CO2 signal can reflect CPR effectiveness but is also dependent on airway patency. The maximal EtCO2 recorded between consecutive ventilator breaths best reflects alveolar CO2.

Для цитирования: Grieco Domenico L, J Brochard Laurent, Drouet Adrien, Telias Irene, Delisle Stéphane, Bronchti Gilles, Ricard Cecile, Rigollot Marceau, Badat Bilal, Ouellet Paul, Charbonney Emmanuel, Mancebo Jordi, Mercat Alain, Savary Dominique, Richard Jean-Christophe M. Intrathoracic Airway Closure Impacts CO2 Signal and Delivered Ventilation during Cardiopulmonary Resuscitation.. American journal of respiratory and critical care medicine. 2019. DOI: 10.1164/rccm.201806-1111oc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.