MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2018.07.006

Медицинская библиотека · Heart rhythm · 2018

Leadless pacemaker implantation after explantation of infected conventional pacemaker systems: A viable solution?

Beurskens Niek E G, Tjong Fleur V Y, Dasselaar Kosse J, Kuijt Wichert J, Wilde Arthur A M, Knops Reinoud E

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Conventional cardiac device infections are increasing in incidence, causing significant morbidity and mortality. Leadless pacemaker (LP) therapy may provide new opportunities for the management of pacemaker (PM) infections as it does not require implantation of transvenous leads and a pectoral pocket.

OBJECTIVE

We sought to evaluate the effect of early and late LP implantation in patients diagnosed with device infection.

METHODS

Patients receiving an LP at our center after conventional PM lead extraction due to infection between December 1, 2013 and November 30, 2017 were included.

RESULTS

A total of 17 patients (mean age 77.4 ± 7.77 years) underwent LP implantation (ie, 11 with Nanostim leadless cardiac pacemaker [Abbott, Chicago, IL] and 6 with Micra transcatheter pacing system [Medtronic, Minneapolis, MN]) after successful PM system explantation. In 9 PM-dependent patients, a temporary transvenous pacing system was placed as a bridge to permanent LP implantation. Early LP implantation was performed in 6 patients (<1 week), and in the remaining patients, the LP was placed at a later stage (>1 week). All patients experienced no LP infection during a mean follow-up of 16 ± 12 months, including 7 patients with a history of recurrent device infections with a mean follow-up of 20 ± 14 months.

CONCLUSION

Early and late LP placement after infected conventional pacing system explantation was a viable option in our case series. This therapy may provide an alternative strategy in the management of device infection, if confirmed by subsequent prospective randomized trials, particularly for patients who are PM dependent or have a history of recurrent device infections.

Для цитирования: Beurskens Niek E G, Tjong Fleur V Y, Dasselaar Kosse J, Kuijt Wichert J, Wilde Arthur A M, Knops Reinoud E. Leadless pacemaker implantation after explantation of infected conventional pacemaker systems: A viable solution?. Heart rhythm. 2018. DOI: 10.1016/j.hrthm.2018.07.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.