Journal of interventional cardiology · 2018
Valve-in-valve transcatheter aortic valve implantation with CoreValve/Evolut R© for degenerated small versus bigger bioprostheses.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Scholtz Smita, Piper Cornelia, Horstkotte Dieter, Gummert Jan, Ensminger Stephan M, Börgermann Jochen, Scholtz Werner
Аннотация
OBJECTIVES: We present our single center experience with Medtronic CoreValve and Evolut R regarding procedural outcome and 3 years follow-up in patients with degenerated bioprostheses.
METHODS: From 1645 patients who underwent transfemoral TAVI at our institution between February 2009 and December 2016, 37 patients with degenerated bioprosthesis were treated with Medtronic CoreValve/Evolut R. All data concerning baseline characteristic, procedural outcomes and follow-up were entered into a dedicated database.
RESULTS: Mean age was 83.9 ± 4.4 years and patients showed an average logistic EuroSCORE of 33.2 ± 16.7%. Successful ViV deployment was achieved in all cases, a permanent pacemaker was implanted in 16.2%, no periinterventional stroke and no coronary obstruction occurred. Mortality at 30 days was 2.7%, at 1-year follow-up 5.7% and at three years 13.5%. Depending on bioprosthesis size <23 mm versus ≥23 mm echocardiographic mean gradients post implantation were significantly higher in the smaller bioprostheses, 22.8 mmHg ± 9.4 mmHg versus 15.1 ± 7.1, P = 0.013.
CONCLUSION: ViV-TAVI with CoreValve/R is demonstrated to be safe and effective in terms of no coronary obstruction and very low mortality up to 3 years despite slightly higher mean transprosthetic gradients especially in very small bioprostheses.
METHODS: From 1645 patients who underwent transfemoral TAVI at our institution between February 2009 and December 2016, 37 patients with degenerated bioprosthesis were treated with Medtronic CoreValve/Evolut R. All data concerning baseline characteristic, procedural outcomes and follow-up were entered into a dedicated database.
RESULTS: Mean age was 83.9 ± 4.4 years and patients showed an average logistic EuroSCORE of 33.2 ± 16.7%. Successful ViV deployment was achieved in all cases, a permanent pacemaker was implanted in 16.2%, no periinterventional stroke and no coronary obstruction occurred. Mortality at 30 days was 2.7%, at 1-year follow-up 5.7% and at three years 13.5%. Depending on bioprosthesis size <23 mm versus ≥23 mm echocardiographic mean gradients post implantation were significantly higher in the smaller bioprostheses, 22.8 mmHg ± 9.4 mmHg versus 15.1 ± 7.1, P = 0.013.
CONCLUSION: ViV-TAVI with CoreValve/R is demonstrated to be safe and effective in terms of no coronary obstruction and very low mortality up to 3 years despite slightly higher mean transprosthetic gradients especially in very small bioprostheses.