m+Medelevator.RU
← Поиск публикаций
BMJ open · 2018

Major determinant of the occurrence of pacing-induced cardiomyopathy in complete atrioventricular block: a multicentre, retrospective analysis over a 15-year period in South Korea.

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kim Jun Hyung, Kang Ki-Woon, Chin Jung Yeon, Kim Tae-Seok, Park Jae-Hyeong, Choi Yu Jeong

Аннотация

OBJECTIVES: The predictors of pacing-induced cardiomyopathy (PICM) for complete atrioventricular block (CAVB) have not yet been defined. The aim of this study was to investigate the major determinant of the occurrence of PICM.

SETTING: This is a multicentre, retrospective analysis of CAVB from tertiary referral centres in Daejeon, South Korea.

PARTICIPANTS: A cohort of 900 consecutive patients with an implanted pacemaker was collected from December 2001 to August 2015. Of these, a total of 130 patients with CAVB with pacing-dependent rhythm who underwent ECG and echocardiogram before and after implantation were analysed for the occurrence of PICM.

OUTCOME MEASURES: Cox proportional hazards models evaluated the determinant of PICM by ECG, device parameters and echocardiogram over a mean of 4.5 years.

RESULTS: PICM was observed in 16.1% (n=21) of all patients with CAVB (age, 64±11 years; male, 36.2%). The preimplant left ventricular (LV) ejection fraction (66%±9% vs 66%±8%) and non-apical pacing (40.4% vs 33.3%) were similar; however, the native QRS duration (124±34 ms vs 149±32 ms) and the paced QRS duration (pQRSd) (139±29 ms vs 167±28 ms) were significantly different between the two groups. The postimplant LV ejection fraction (61%±7% vs 31%±8%) was also significantly different at the end of follow-up. A pQRSd significantly correlated with PICM (HR 1.05, 95% CI 1.02 to 1.09, P=0.001). A pQRSd with a cut-off value of above 140 ms had a sensitivity of 95% while a pQRSd with a cut-off value of above 167 ms had a specificity of 90% for PICM.

CONCLUSION: In patients with CAVB with pacing-dependent rhythm, regardless of the pacing site, the pQRSd is a major determinant of the occurrence of PICM.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты