MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2017.06.004

Медицинская библиотека · Heart rhythm · 2017

Low lateral thoracic site for cardiac implantable electronic device implantation: A viable alternative in patients with limited access options after infected device extraction.

Liang Jackson J, Schaller Robert D, Modi Danesh S, Enriquez Andres, Supple Gregory E, Cooper Joshua M

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Device reimplantation after extraction because of cardiac implantable electronic device (CIED) infection in pacemaker-dependent patients can be challenging in individuals with limited access options.

OBJECTIVE

The purpose of this study was to describe a straightforward, low lateral thoracic implantation technique for patients with a patent axillary vein but unavailable bilateral pectoral sites.

METHODS

Nine pacemaker-dependent patients (mean age 70 ± 13 years, 7 male) who underwent CIED extraction and low lateral thoracic reimplantation in whom bilateral pectoral sites were unavailable were included in the study.

RESULTS

Extraction was performed a median of 10 (interquartile range [IQR] 8-13) days before CIED reimplantation (4 dual-chamber, 3 single-chamber, 2 cardiac resynchronization therapy). The new generator was implanted in the low lateral thoracic region ipsilateral to the extracted generator in 7 patients (78%) and contralateral in 2 patients (22%), via a subcutaneous pocket in 6 (67%) and submuscular pocket in 3 (33%). Median procedure duration was 85 (IQR 61-116) minutes, median fluoroscopy time was 7.2 (IQR 5.7-10.9), minutes and median fluoroscopy exposure was 26.0 (IQR 10.0-110.5) mGy. No acute complications occurred. Over median follow-up of 92 (IQR 31-131) days, 1 patient experienced right atrial lead dislodgment (122 days postimplantation) requiring lead revision. No patients experienced recurrent device infection.

CONCLUSION

In pacemaker-dependent patients with limited prepectoral and vascular access options, a low lateral thoracic implantation site is a viable alternative to surgical epicardial or femoral pacing systems. This simple implantation technique is a safe and effective option in selected patients who require a single-chamber, dual-chamber, or biventricular pacemaker or implantable cardioverter-defibrillator.

Для цитирования: Liang Jackson J, Schaller Robert D, Modi Danesh S, Enriquez Andres, Supple Gregory E, Cooper Joshua M. Low lateral thoracic site for cardiac implantable electronic device implantation: A viable alternative in patients with limited access options after infected device extraction.. Heart rhythm. 2017. DOI: 10.1016/j.hrthm.2017.06.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.