m+Medelevator.RU
← Поиск публикаций
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2017

Short-term mechanical circulatory support as a bridge to durable left ventricular assist device implantation in refractory cardiogenic shock: a systematic review and meta-analysis.

СтатьяМетаанализСистематический обзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

den Uil Corstiaan A, Akin Sakir, Jewbali Lucia S, Dos Reis Miranda Dinis, Brugts Jasper J, Constantinescu Alina A, Kappetein Arie Pieter, Caliskan Kadir

Аннотация

Short-term mechanical circulatory support (MCS) is increasingly used as a bridge to decision in patients with refractory cardiogenic shock. Subsequently, these patients might be bridged to durable MCS either as a bridge to candidacy/transplantation, or as destination therapy. The aim of this study was to review support duration and clinical outcome of short-term MCS in cardiogenic shock, and to analyse application of this technology as a bridge to long-term cardiac support (left ventricular assist device, LVAD) from 2006 till June 2016. Using Cochrane Register of Trials, Embase and Medline, a systematic review was performed on patients with cardiogenic shock from acute myocardial infarction, end-stage cardiomyopathy, or acute myocarditis, receiving short-term MCS. Studies on periprocedural, post-cardiotomy and cardiopulmonary resuscitation support were excluded. Thirty-nine studies, mainly registries of heterogeneous patient populations (n = 4151 patients), were identified. Depending on the device used (intra-aortic balloon pump, TandemHeart, Impella 2.5, Impella 5.0, CentriMag and peripheral veno-arterial extracorporeal membrane oxygenation), mean support duration was (range) 1.6-25 days and the mean proportion of short-term MCS patients discharged was (range) 45-66%. The mean proportion of bridge to durable LVAD was (range) 3-30%. Bridge to durable LVAD was most frequently performed in patients with end-stage cardiomyopathy (22 [12-35]%). We conclude that temporary MCS can be used to bridge patients with cardiogenic shock towards durable LVAD. Clinicians are encouraged to share their results in a large multicentre registry in order to investigate optimal device selection and best duration of support.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты