MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajur.2022.11.006

Медицинская библиотека · Asian journal of urology · 2023

The optimal stent pusher position to achieve successful ureteral stent insertion under fluoroscopic guidance.

Taguchi Makoto, Yasuda Kaneki, Kinoshita Hidefumi

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To examine factors to predict the optimal stent pusher position when inserting ureteral stents under fluoroscopy.

METHODS

We retrospectively reviewed 327 patients who underwent ureteral stent insertion. We considered the pubic bone as a useful anatomical landmark to insert ureteral stents under fluoroscopic guidance. Thus, we categorized patients into three groups (proximal, middle, and distal groups) according to the position of the radiopaque tip of the push catheter when inserting the ureteral stent. Success was defined as a completely curled ureteral stent tail. We compared stent insertion success rates among the three groups. A multivariate analysis was performed to identify the factors affecting stent insertion success.

RESULTS

In men, 36 (63.2%) cases were deemed successful in the proximal group compared with 40 (80.0%) cases in the middle group and 12 (20.7%) cases in the distal group (p<0.001). In women, 26 (45.6%) cases were deemed successful in the proximal group compared with 54 (98.2%) cases in the middle group and 38 (76.0%) cases in the distal group (p<0.001). With the multivariate analysis, the stent pusher position was the most significant factor influencing successful stent insertion (men: odds ratio 6.00, 95% confidence interval 2.66-13.51, p<0.001; women: odds ratio 37.80, 95% confidence interval 4.94-289.22, p<0.001).

CONCLUSION

The position of the stent pusher affects stent insertion success. The middle of the pubic symphysis is the optimal position for the radiopaque tip of the pusher when inserting ureteral stents under fluoroscopic guidance.

Для цитирования: Taguchi Makoto, Yasuda Kaneki, Kinoshita Hidefumi. The optimal stent pusher position to achieve successful ureteral stent insertion under fluoroscopic guidance.. Asian journal of urology. 2023. DOI: 10.1016/j.ajur.2022.11.006.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.