DOI 10.1016/j.healun.2016.01.1225

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2016

Right ventricular afterload sensitivity dramatically increases after left ventricular assist device implantation: A multi-center hemodynamic analysis.

Houston Brian A, Kalathiya Rohan J, Hsu Steven, Loungani Rahul, Davis Mary E, Coffin Samuel T, Haglund Nicholas, Maltais Simon, Keebler Mary E, Leary Peter J, Judge Daniel P, Stevens Gerin R, Rickard John, Sciortino Chris M, Whitman Glenn J, Shah Ashish S, Russell Stuart D, Tedford Ryan J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Right ventricular (RV) failure is a source of morbidity and mortality after left ventricular assist device (LVAD) implantation. In this study we sought to define hemodynamic changes in afterload and RV adaptation to afterload both early after implantation and with prolonged LVAD support.

METHODS

We reviewed right heart catheterization (RHC) data from participants who underwent continuous-flow LVAD implantation at our institutions (n = 244), excluding those on inotropic or vasopressor agents, pulmonary vasodilators or additional mechanical support at any RHC assessment. Hemodynamic data were assessed at 5 time intervals: (1) pre-LVAD (within 6 months); (2) early post-LVAD (0 to 6 months); (3) 7 to 12 months; (4) 13 to 18 months; and (5) very late post-LVAD (18 to 36 months).

RESULTS

Sixty participants met the inclusion criteria. All measures of right ventricular load (effective arterial elastance, pulmonary vascular compliance and pulmonary vascular resistance) improved between the pre- and early post-LVAD time periods. Despite decreasing load and pulmonary artery wedge pressure (PAWP), RAP remained unchanged and the RAP:PAWP ratio worsened early post-LVAD (0.44 [0.38, 0.63] vs 0.77 [0.59, 1.0], p < 0.001), suggesting a worsening of RV adaptation to load. With continued LVAD support, both RV load and RAP:PAWP decreased in a steep, linear and dependent manner.

CONCLUSIONS

Despite reducing RV load, LVAD implantation leads to worsened RV adaptation. With continued LVAD support, both RV afterload and RV adaptation improve, and their relationship remains constant over time post-LVAD. These findings suggest the RV afterload sensitivity increases after LVAD implantation, which has major clinical implications for patients struggling with RV failure.

Для цитирования: Houston Brian A, Kalathiya Rohan J, Hsu Steven, Loungani Rahul, Davis Mary E, Coffin Samuel T, Haglund Nicholas, Maltais Simon, Keebler Mary E, Leary Peter J, Judge Daniel P, Stevens Gerin R, Rickard John, Sciortino Chris M, Whitman Glenn J, Shah Ashish S, Russell Stuart D, Tedford Ryan J. Right ventricular afterload sensitivity dramatically increases after left ventricular assist device implantation: A multi-center hemodynamic analysis.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2016. DOI: 10.1016/j.healun.2016.01.1225.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.