m+Medelevator.RU
← Поиск публикаций
Journal of cardiovascular electrophysiology · 2021

Zero-fluoroscopy ablation in patients with cardiac electronic implantable devices.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shimamoto Keiko, Yamagata Kenichiro, Wakamiya Akinori, Ueda Nobuhiko, Kamakura Tsukasa, Wada Mitsuru, Inoue-Yamada Yuko, Miyamoto Koji, Nagase Satoshi, Kusano Kengo F

Аннотация

INTRODUCTION: Utilizing a three-dimensional (3-D) mapping system and intracardiac echocardiography (ICE) has allowed ablation procedures with less or without fluoroscopy; however, there is limited data for patients with cardiac electronic implantable device (CIED) leads regarding the suspected risk of lead injury. Therefore, we sought to explore technics to perform safe trans-septal approach and catheter manipulation technique in patients with CIED leads.

METHODS AND RESULTS: This study comprised 49 consecutive patients (59% males, median 73 years old) with CIED who underwent catheter ablation for supraventricular tachycardia requiring the trans-septal approach, 15 without fluoroscopy (zero-fluoro group), and 34 with fluoroscopy (conventional-fluoro group), between July 2019 and April 2021. All procedures were performed under a 3-D mapping system and ICE guidance. We compared the differences in treatment and development of complications between the two groups. The procedures were for atrial fibrillation (82%) and atrial tachycardia (76%). Coronary sinus catheter insertion and the trans-septal procedure were successfully performed in all patients. The median time from venipuncture to trans-septal procedure (zero-fluoro vs. conventional-fluoro group: 28 [18-37] min vs. 24 [21-31] min, p = .70), total procedure time (231 [142-274] min vs. 175 [163-225] min, p = .63), and the acute procedural success rate (100% vs. 97%, p = 1.00) did not differ between both groups. No patient showed lead-related complications in both groups.

CONCLUSION: This is the first study to show zero-fluoro ablation for supraventricular arrhythmia using 3-D mapping and ICE in patients with CIED leads was feasible under careful catheter manipulation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты