MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/(sici)1097-4636(199911)47:2<260::aid-jbm17>3.0.co;2-j

Медицинская библиотека · Journal of biomedical materials research · 1999

Novel synthetic meshwork for glaucoma treatment. I. Design and preliminary in vitro and in vivo evaluation of various expanded poly(tetrafluoroethylene) materials.

Jallet V, Gautier S E, Parel J M, Matsui T, Haefliger I, Kondo H, Kato H, Savoldelli M, Pouliquen Y

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

A novel drainage implant for glaucoma filtering surgery (MESH) is proposed. After various expanded poly(tetrafluoroethylene) (e-PFTE) materials were evaluated, the feasibility and the short-term safety of the technique were assessed in this first pilot study in the rabbit. The porous structure and the in vitro resistance to aqueous flow of seven different e-PTFE membranes (5-80 microm average pore size) were compared. Eight Dutch pigmented rabbits were implanted with the T-shaped MESH implants made from either 20- or 50-microm average pore size e-PTFE membranes. Clinical examination, intraocular pressure (IOP) measurements, and histology analyses were performed over a period of 3 months. The contralateral nonoperated eyes served as controls. MESH implantation took less than 7 min. No postoperative hypotony, migration, or extrusion of the implant and no intraocular inflammation or infection occurred. A significant IOP reduction in the implanted eyes was obtained past postoperative day 21 with the 20-microm material implant. The drainage efficacy was correlated with the degree of colonization of the porous materials and the inner spacing of the implant as observed by histology. With a filtering patency 3 times longer than conventional trabeculectomy and laser sclerectomy, MESH surgery is a promising technique for glaucoma treatment. Further studies are underway to enhance the device efficacy and understand the mechanism of filtration.

Для цитирования: Jallet V, Gautier S E, Parel J M, Matsui T, Haefliger I, Kondo H, Kato H, Savoldelli M, Pouliquen Y. Novel synthetic meshwork for glaucoma treatment. I. Design and preliminary in vitro and in vivo evaluation of various expanded poly(tetrafluoroethylene) materials.. Journal of biomedical materials research. 1999. DOI: 10.1002/(sici)1097-4636(199911)47:2<260::aid-jbm17>3.0.co;2-j.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.