DOI 10.1016/s0886-3350(98)80055-2
Efficacy of synthetic and biological bioadhesives in scleral tunnel phacoemulsification in eyes with high myopia.
Аннотация
PURPOSE: To study the efficacy of a synthetic (cyanoacrylate) and a biological (fibrinogen) bioadhesive in sealing scleral tunnel incisions in cataract surgery.
SETTING
Private institution with academic orientation.
METHODS
This controlled clinical study comprised 126 eyes with high myopia (axial length > 28.0 mm) divided into three groups based on method of incision closure 10-1 nylon anchor suture; cyanoacrylate (Histoacryl); fibrinogen (Tissucol). Phacoemulsification was done through a double-valved scleral tunnel incision with an 8.0 mm arc. In all eyes, a hyperconcave, 7.0 mm optic, posterior chamber intraocular lens was implanted.
RESULTS
Mean induced astigmatism at 12 weeks was 0.18 diopter (D) in the suture group, 0.50 D in the cyanoacrylate group, and 0.43 D in the fibrinogen group. The difference between the bioadhesive groups and the suture group was not significant. A mild inflammatory reaction occurred in the cyanoacrylate group. In the fibrinogen group, 3 eyes developed postoperative hypotony requiring reclosing of the incision with sutures and 5 eyes developed intraoperative hypotony requiring suture closure. These eyes were not included in the refractive analysis. These complications led to the suspension of the fibrinogen portion of the study after uneventful use of the bioadhesive in 26 eyes.
CONCLUSION
The results of this study indicate that bioadhesives, especially synthetic ones such as cyanoacrylate, are an effective alternative to sutures in scleral tunnel cataract surgery. Future improvements in bioadhesives could extend their application to other ocular incision types.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.