Kato Daniel Massamatsu Pianovski, Lorusso Liziane, Bruns Rafael Frederico, Pinhat Elisa Chicareli, Dalla Costa Natália Roberta Andrade, Pletsch Letícia, Araujo Júnior Edward
Аннотация
PURPOSE: To compare the performance of a local estimated fetal weight curve with curves established for other populations to predict small for gestational age (SGA) fetuses.
METHODS: A retrospective and cross-sectional study involving 231 fetuses in which the performance of a local curve (proposed model) was compared with the Hadlock and Intergrowth-21st curves in the prediction of SGA fetuses, by applying them to a population of high-risk pregnant woman with HIV/AIDS. For each model, a receiver operating characteristic curve was adjusted, considering the SGA classification by the neonatal Intergrowth method as the gold standard, and the area under the curve (AUC) was calculated.
RESULTS: The models presented linear correlations with each other. The agreement of the proposed model with Hadlock was very good (kappa = 0.83), whereas the proposed model and Intergrowth-21st had moderate agreement (kappa = 0.44). The SGA fetus detection sensitivities of the proposed model and Hadlock were 61.9% and 57.1%, with specificity of 84.1% and 86.2% and accuracy of 80.1% and 81%, respectively, without statistical difference. The sensitivity of the Intergrowth-21st model was 33.3%, while the accuracy was 85.7% and the specificity was 97.4%. The AUC estimated values for the Hadlock, proposed, and Intergrowth-21st models were 0.834, 0.832, and 0.835, respectively.
CONCLUSION: The proposed model and Hadlock were interchangeable in the prediction of SGA fetuses and superior to the Intergrowth-21st model.
METHODS: A retrospective and cross-sectional study involving 231 fetuses in which the performance of a local curve (proposed model) was compared with the Hadlock and Intergrowth-21st curves in the prediction of SGA fetuses, by applying them to a population of high-risk pregnant woman with HIV/AIDS. For each model, a receiver operating characteristic curve was adjusted, considering the SGA classification by the neonatal Intergrowth method as the gold standard, and the area under the curve (AUC) was calculated.
RESULTS: The models presented linear correlations with each other. The agreement of the proposed model with Hadlock was very good (kappa = 0.83), whereas the proposed model and Intergrowth-21st had moderate agreement (kappa = 0.44). The SGA fetus detection sensitivities of the proposed model and Hadlock were 61.9% and 57.1%, with specificity of 84.1% and 86.2% and accuracy of 80.1% and 81%, respectively, without statistical difference. The sensitivity of the Intergrowth-21st model was 33.3%, while the accuracy was 85.7% and the specificity was 97.4%. The AUC estimated values for the Hadlock, proposed, and Intergrowth-21st models were 0.834, 0.832, and 0.835, respectively.
CONCLUSION: The proposed model and Hadlock were interchangeable in the prediction of SGA fetuses and superior to the Intergrowth-21st model.