OBJECTIVE

By using ultrasound strain rate (SR) imaging to evaluate the left atrial (LA) reservoir and pump function after catheter ablation (CA) with persistent atrial fibrillation (PAF).

METHODS

A total of 45 patients with PAF underwent echocardiography examination before and after ablation as well as during 6 months of follow-up. Peak SR was measured at each LA segment (septal, lateral, anterior, inferior and posterior) during systole (LAs) and late diastole (LAa).

RESULTS

During 6 months after CA, 30 patients were free of atrial fibrillation recurrence (AFR). left atrial area index (LAAI), left atrial maximum volume index (LAVImax), and E/Ea were obviously higher in patients with before CA, left atrial ejection fraction (LAEF), SR-LAs were lower than in normal cases, the SR-LAa was disappeared. Shortly after ablation, SR-LAa was recovered, and SR-LAs was reduced compared to those at baseline. At midterm follow-up, LAEF and SR-LAs were still lower than the control group, and LAAI and LAVImax were higher. SR-LAa was recovered slowly over time, but still lower.

CONCLUSION

LA reservoir function was seriously damaged and LA pump function disappeared in patients with PAF. LA reservoir function impairment appeared shortly after ablation, it showed improvement at midterm follow-up, but some degree of damage to the LA reservoir and pump function was still present. Speckle tracking imaging is a feasible technique for the assessment of LA function in patients with PAF, which is a potentially valuable clinical tool to assist in the early detection of atrial remodelling and reverse remodelling.

Для цитирования: Zhong Xiao-Fang, Liu Dong-Sheng, Zheng Ying-Qi, Peng Gui-Juan, Sheng Yuan-Yuan, Chen Li-Xin, Liu Ying-Ying. Left atrial reservoir and pump function after catheter ablation with persistent atrial fibrillation: a two-dimensional speckle tracking imaging study.. Acta cardiologica. 2022. DOI: 10.1080/00015385.2022.2076308.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.