General thoracic and cardiovascular surgery · 2022
Higher F-wave frequency associates with poor procedural success rate after Maze procedure.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Usui Rena, Mutsuga Masato, Narita Yuji, Tokuda Yoshiyuki, Terazawa Sachie, Ito Hideki, Uchida Wataru, Inden Yasuya, Murohara Toyoaki, Usui Akihiko
Аннотация
OBJECTIVES: Persistent atrial fibrillation (AF) causes atrial remodeling, which causes myocardial fibrosis and micro-reentry. Fibrosis may reduce wave voltage and micro-reentry may enhance the dominant frequency (DF) of the F-wave. We investigated whether the DF predicts procedural success by the Maze procedure.
METHODS: In 138 consecutive patients who underwent mitral valve surgery and a modified Cox-Maze III procedure for persistent AF in Nagoya University in 2002-2018, 96 (70%) were successfully cardioverted (group S); 42 had persistent or relapsed AF after surgery (group F). Patient data were compared between the groups. Cut-off values were determined by an ROC analysis and predictors of procedural success were evaluated. The DF was obtained from the F-wave of V1 by a high-speed Fourier analysis using the CEPAS software program.
RESULTS: Group F showed a significantly larger LA diameter, better LVEF, lower F-wave voltage, higher DF, and longer duration of AF. The cut-off values were as follows: LA diameter, 56 mm; EF, 64.5%; F-wave voltage, 0.13 mV; DF, 7.3 Hz; and duration of AF, 44 months. Each factor showed statistical significance in a univariate analysis; DF lost significance in the multivariate analysis. The higher (DF ≥ 7.3 Hz) and lower voltage group (≤ 0.13 mV) showed the worst procedural success rate (36%), while the lower DF (< 7.3 Hz) and higher voltage group (> 0.13 mV) showed a good rate (86%).
CONCLUSIONS: The DF of the F-wave is a useful predictor of procedural success after the Maze procedure in addition to the voltage of F-wave.
METHODS: In 138 consecutive patients who underwent mitral valve surgery and a modified Cox-Maze III procedure for persistent AF in Nagoya University in 2002-2018, 96 (70%) were successfully cardioverted (group S); 42 had persistent or relapsed AF after surgery (group F). Patient data were compared between the groups. Cut-off values were determined by an ROC analysis and predictors of procedural success were evaluated. The DF was obtained from the F-wave of V1 by a high-speed Fourier analysis using the CEPAS software program.
RESULTS: Group F showed a significantly larger LA diameter, better LVEF, lower F-wave voltage, higher DF, and longer duration of AF. The cut-off values were as follows: LA diameter, 56 mm; EF, 64.5%; F-wave voltage, 0.13 mV; DF, 7.3 Hz; and duration of AF, 44 months. Each factor showed statistical significance in a univariate analysis; DF lost significance in the multivariate analysis. The higher (DF ≥ 7.3 Hz) and lower voltage group (≤ 0.13 mV) showed the worst procedural success rate (36%), while the lower DF (< 7.3 Hz) and higher voltage group (> 0.13 mV) showed a good rate (86%).
CONCLUSIONS: The DF of the F-wave is a useful predictor of procedural success after the Maze procedure in addition to the voltage of F-wave.