MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11748-022-01836-0

Медицинская библиотека · General thoracic and cardiovascular surgery · 2022

Higher F-wave frequency associates with poor procedural success rate after Maze procedure.

Usui Rena, Mutsuga Masato, Narita Yuji, Tokuda Yoshiyuki, Terazawa Sachie, Ito Hideki, Uchida Wataru, Inden Yasuya, Murohara Toyoaki, Usui Akihiko

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Persistent atrial fibrillation (AF) causes atrial remodeling, which causes myocardial fibrosis and micro-reentry. Fibrosis may reduce wave voltage and micro-reentry may enhance the dominant frequency (DF) of the F-wave. We investigated whether the DF predicts procedural success by the Maze procedure.

METHODS

In 138 consecutive patients who underwent mitral valve surgery and a modified Cox-Maze III procedure for persistent AF in Nagoya University in 2002-2018, 96 (70%) were successfully cardioverted (group S); 42 had persistent or relapsed AF after surgery (group F). Patient data were compared between the groups. Cut-off values were determined by an ROC analysis and predictors of procedural success were evaluated. The DF was obtained from the F-wave of V1 by a high-speed Fourier analysis using the CEPAS software program.

RESULTS

Group F showed a significantly larger LA diameter, better LVEF, lower F-wave voltage, higher DF, and longer duration of AF. The cut-off values were as follows: LA diameter, 56 mm; EF, 64.5%; F-wave voltage, 0.13 mV; DF, 7.3 Hz; and duration of AF, 44 months. Each factor showed statistical significance in a univariate analysis; DF lost significance in the multivariate analysis. The higher (DF ≥ 7.3 Hz) and lower voltage group (≤ 0.13 mV) showed the worst procedural success rate (36%), while the lower DF (< 7.3 Hz) and higher voltage group (> 0.13 mV) showed a good rate (86%).

CONCLUSIONS

The DF of the F-wave is a useful predictor of procedural success after the Maze procedure in addition to the voltage of F-wave.

Для цитирования: Usui Rena, Mutsuga Masato, Narita Yuji, Tokuda Yoshiyuki, Terazawa Sachie, Ito Hideki, Uchida Wataru, Inden Yasuya, Murohara Toyoaki, Usui Akihiko. Higher F-wave frequency associates with poor procedural success rate after Maze procedure.. General thoracic and cardiovascular surgery. 2022. DOI: 10.1007/s11748-022-01836-0.