MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-022-01234-9

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022

Radiofrequency ablation using the second-generation temperature-controlled diamond tip system in paroxysmal and persistent atrial fibrillation: results from FASTR-AF.

Neuzil Petr, Poty Herve, de Chillou Christian, Petru Jan, Getman Michael K, Liu Shufeng, Funasako Moritoshi, Durand-Dubief Alexis, Combes Stéphane, Albenque Jean-Paul

Многоцентровое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Catheter ablation (CA) technology development reflects the need to improve the effectiveness of atrial fibrillation (AF) treatment. Recently, the DiamondTemp Ablation (DTA) RF generator software was updated with a more responsive power ramp.

METHODS

DIAMOND FASTR-AF was a prospective, single-arm, multicenter trial. This study sought to characterize the performance of the updated DTA system for the treatment of patients with drug-refractory paroxysmal and persistent AF (PAF and PsAF). The primary effectiveness endpoint was freedom from atrial arrhythmia recurrence following a 90-day blanking period through 12 months, and the primary safety endpoint was a composite of serious adverse events.

RESULTS

In total, 60 subjects (34 PAF and 26 PsAF) underwent CA at three centers. Patients were 71.7% male, (age 63.9 ± 10.2 years, with an AF diagnosis duration 3.1 ± 3.9 years and left atrial size 4.4 ± 0.8 cm). Pulmonary vein isolation-only ablation strategy was performed in 34 (56.7%) subjects. The procedural characteristics show a procedure time 90.8 ± 31.6 min, total RF time 14.7 ± 7.7 min, ablation duration 10.7 ± 3.6 s, and fluid infusion 284.7 ± 111.5 ml. The serious adverse event rate was 8.3% (5/60), 3 pulmonary edema and 2 extended hospitalizations. Freedom from atrial arrhythmia recurrence was achieved in 67.6% of subjects by 12 months.

CONCLUSIONS

The updated DTA system demonstrated long-term safety and effectiveness through 12 months of post-ablation follow-up for patients with atrial fibrillation. Additionally, procedures were demonstrated to be highly efficient with short procedure times and low levels of fluid infusion.

TRIAL REGISTRATION: Sponsored by Medtronic, Inc.; FASTR-AF ClinicalTrials.gov; NCT03626649.

Для цитирования: Neuzil Petr, Poty Herve, de Chillou Christian, Petru Jan, Getman Michael K, Liu Shufeng, Funasako Moritoshi, Durand-Dubief Alexis, Combes Stéphane, Albenque Jean-Paul. Radiofrequency ablation using the second-generation temperature-controlled diamond tip system in paroxysmal and persistent atrial fibrillation: results from FASTR-AF.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2022. DOI: 10.1007/s10840-022-01234-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.