MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.14495

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2022

Feasibility and safety of left atrial posterior wall isolation with a new Cryoballoon technology in patients with persistent atrial fibrillation.

Bisignani Antonio, Pannone Luigi, Miraglia Vincenzo, Sieira Juan, Iacopino Saverio, Bala Gezim, Ströker Erwin, Overeinder Ingrid, Almorad Alexandre, Gauthey Anaïs, Monaco Cinzia, Paparella Gaetano, Osório Thiago Guimarães, Sorgente Antonio, Jordaens Luc, Brugada Pedro, Chierchia Gian-Battista, Asmundis Carlo de

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Left atrial posterior wall isolation (LAPWI) is often performed in addition to pulmonary vein isolation (PVI) in the setting of persistent atrial fibrillation (AF) ablation. The aim of this study was to evaluate the feasibility and safety of a new cryoballoon ablation system in achieving PVI + LAPWI isolation.

METHODS

The study was a prospective, non-randomized, single center study. Forty consecutive patients, undergoing PVI + LAPWI with the novel POLARx™, were compared to 40 consecutive patients who underwent the same procedure with the established Arctic Front Advance PRO™.

RESULTS

Acute isolation was achieved in all PVs in both groups and left posterior wall isolation (LAPWI) was achieved in 38 patients (95%) in the POLARx group and in 36 patients (90%) in Arctic Front group. Procedural outcomes were similar between both groups, except for lower temperatures during cryoenergy in the POLARx group, for both pulmonary vein isolation (PVI) and LAPWI.

CONCLUSION

LAPWI + PVI with the novel POLARx™ Cryoballoon is feasible and safe; the results are comparable with the Arctic Front Advance PRO™ system.

Для цитирования: Bisignani Antonio, Pannone Luigi, Miraglia Vincenzo, Sieira Juan, Iacopino Saverio, Bala Gezim, Ströker Erwin, Overeinder Ingrid, Almorad Alexandre, Gauthey Anaïs, Monaco Cinzia, Paparella Gaetano, Osório Thiago Guimarães, Sorgente Antonio, Jordaens Luc, Brugada Pedro, Chierchia Gian-Battista, Asmundis Carlo de. Feasibility and safety of left atrial posterior wall isolation with a new Cryoballoon technology in patients with persistent atrial fibrillation.. Pacing and clinical electrophysiology : PACE. 2022. DOI: 10.1111/pace.14495.