MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chest.2020.07.051

Медицинская библиотека · Chest · 2020

Development of an Accurate Bedside Swallowing Evaluation Decision Tree Algorithm for Detecting Aspiration in Acute Respiratory Failure Survivors.

Moss Marc, White S David, Warner Heather, Dvorkin Daniel, Fink Daniel, Gomez-Taborda Stephanie, Higgins Carrie, Krisciunas Gintas P, Levitt Joseph E, McKeehan Jeffrey, McNally Edel, Rubio Alix, Scheel Rebecca, Siner Jonathan M, Vojnik Rosemary, Langmore Susan E

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The bedside swallowing evaluation (BSE) is an assessment of swallowing function and airway safety during swallowing. After extubation, the BSE often is used to identify the risk of aspiration in acute respiratory failure (ARF) survivors.

RESEARCH QUESTION: We conducted a multicenter prospective study of ARF survivors to determine the accuracy of the BSE and to develop a decision tree algorithm to identify aspiration risk.

STUDY DESIGN AND

METHODS

Patients extubated after ≥ 48 hours of mechanical ventilation were eligible. Study procedures included the BSE followed by a gold standard evaluation, the flexible endoscopic evaluation of swallowing (FEES).

RESULTS

Overall, 213 patients were included in the final analysis. Median time from extubation to BSE was 25 hours (interquartile range, 21-45 hours). The FEES was completed 1 hour after the BSE (interquartile range, 0.5-2 hours). A total of 33% (70/213; 95% CI, 26.6%-39.2%) of patients aspirated on at least one FEES bolus consistency test. Thin liquids were the most commonly aspirated consistency: 27% (54/197; 95% CI, 21%-34%). The BSE detected any aspiration with an accuracy of 52% (95% CI, 45%-58%), a sensitivity of 83% (95% CI, 74%-92%), and negative predictive value (NPV) of 81% (95% CI, 72%-91%). Using recursive partitioning analyses, a five-variable BSE-based decision tree algorithm was developed that improved the detection of aspiration with an accuracy of 81% (95% CI, 75%-87%), sensitivity of 95% (95% CI, 90%-98%), and NPV of 97% (95% CI, 95%-99%).

INTERPRETATION: The BSE demonstrates variable accuracy to identify patients at high risk for aspiration. Our decision tree algorithm may enhance the BSE and may be used to identify patients at high risk for aspiration, yet requires further validation.

TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT02363686; URL: www.clinicaltrials.gov.

Для цитирования: Moss Marc, White S David, Warner Heather, Dvorkin Daniel, Fink Daniel, Gomez-Taborda Stephanie, Higgins Carrie, Krisciunas Gintas P, Levitt Joseph E, McKeehan Jeffrey, McNally Edel, Rubio Alix, Scheel Rebecca, Siner Jonathan M, Vojnik Rosemary, Langmore Susan E. Development of an Accurate Bedside Swallowing Evaluation Decision Tree Algorithm for Detecting Aspiration in Acute Respiratory Failure Survivors.. Chest. 2020. DOI: 10.1016/j.chest.2020.07.051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.