MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1253/circj.cj-21-0608

Медицинская библиотека · Circulation journal : official journal of the Japanese Circulation Society · 2021

Comparison of Cryoballoon and Contact Force-Sensing Radiofrequency Ablation for Persistent Atrial Fibrillation in Clinical Practice.

Kobori Atsushi, Sasaki Yasuhiro, Pak Misun, Ishikura Masahiro, Murai Ryosuke, Okada Taiji, Toyota Toshiaki, Taniguchi Tomohiko, Kim Kitae, Ehara Natsuhiko, Kinoshita Makoto, Kihara Yasuki, Furukawa Yutaka

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Outcomes of cryoballoon ablation for persistent atrial fibrillation (AF) are unclear, especially in Japanese patients, so the effectiveness and safety of cryoballoon ablation in clinical practice were retrospectively compared with those of contact force-sensing radiofrequency (CFRF) ablation including the high-power protocol.

METHODS AND

RESULTS

Consecutive patients with persistent AF were reviewed, and 253 and 265 patients who underwent cryoballoon and CFRF ablation, respectively, were enrolled. The primary endpoint was atrial arrhythmia recurrence. The secondary endpoints were periprocedural complications and repeat ablation. The rate of additional left atrial (LA) ablation after pulmonary vein isolation (PVI) was similar between groups (68.8% cryoballoon vs. 74.0% CFRF, P=0.19). Freedom from atrial arrhythmia recurrence was comparable between groups over a follow-up of 25.5±12.5 months (72.3% cryoballoon vs. 69.8% CFRF; adjusted hazard ratio (HR) 0.85, 95% confidence interval (CI) 0.59-1.21, P=0.36). Outcomes were similar in the subgroups of PVI alone and PVI plus additional LA ablation. LA posterior wall isolation, absence of defragmentation, and low creatine clearance, but not catheter selection, were associated with the primary endpoint. Periprocedural complications (adjusted HR 0.73, 95% CI 0.34-1.54, P=0.41) and repeat ablation (adjusted HR 1.11, 95% CI 0.71-1.74, P=0.64) were similar for both procedures.

CONCLUSIONS

Cryoballoon ablation for persistent AF in Japanese clinical practice had acceptable outcomes comparable to those of advanced CFRF ablation.

Для цитирования: Kobori Atsushi, Sasaki Yasuhiro, Pak Misun, Ishikura Masahiro, Murai Ryosuke, Okada Taiji, Toyota Toshiaki, Taniguchi Tomohiko, Kim Kitae, Ehara Natsuhiko, Kinoshita Makoto, Kihara Yasuki, Furukawa Yutaka. Comparison of Cryoballoon and Contact Force-Sensing Radiofrequency Ablation for Persistent Atrial Fibrillation in Clinical Practice.. Circulation journal : official journal of the Japanese Circulation Society. 2021. DOI: 10.1253/circj.cj-21-0608.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.