m+Medelevator.RU
← Поиск публикаций
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2021

Safety and acute efficacy of cryoballoon ablation for atrial fibrillation at community hospitals.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hoffmann Rainer, Parade Ulli, Bauerle Hansjörg, Winter Klaus-Dieter, Rauschenbach Ulrich, Mischke Karl, Schaefer Carl, Gutleben Klaus-Jürgen, Rana Obaida R, Willich Tobias, Schlößer Marc, Rötzer Alfons, Breithardt Ole A, Middendorf Stefan, Waldecker Berndt, Grove Rainer, Mosa Jörg, Krug Joachim, Imnadze Guram, Saygili Erol, Michaelsen Jochen

Аннотация

AIMS: Pulmonary vein isolation (PVI) using cryoballoon ablation (CBA) is an established procedure for treating symptomatic paroxysmal and persistent atrial fibrillation (AF). The safety and efficacy of PVI performed at community hospitals are unknown. We aimed to determine the safety and acute efficacy of PVI using CBA performed at community hospitals with limited annual case numbers.

METHODS AND RESULTS: This registry study included 1004 consecutive patients who had PVI performed for symptomatic paroxysmal (n = 563) or persistent AF (n = 441) from January 2019 to September 2020 at 20 hospitals. Each hospital performed fewer than 100 CBA-PVI procedures/year according to local standards. Procedural data, efficacy, and complication rates were determined. The mean number of CBA procedures performed/year at each centre was 59 ± 25. The average procedure time was 90.1 ± 31.6 min and the average fluoroscopy time was 19.2 ± 11.4 min. Isolation of all pulmonary veins was documented in 97.9% of patients. The most frequent reason for not achieving complete isolation was development of phrenic nerve palsy. No hospital deaths were observed. Two patients (0.2%) suffered a clinical stroke. Pericardial effusion occurred in six patients (0.6%), two of whom (0.2%) required pericardial drainage. Vascular complications occurred in 24 patients (2.4%), two of whom (0.2%) required vascular surgery. Phrenic nerve palsy occurred in 48 patients (4.8%) and persisted up to hospital discharge in six patients (0.6%).

CONCLUSION: Pulmonary vein isolation procedures for paroxysmal or persistent AF using CBA can be performed at community hospitals with high acute efficacy and low complication rates.