Real-world evaluation of RetCAD deep-learning system for the detection of referable diabetic retinopathy and age-related macular degeneration.

Оценочное исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Taylor Joshua R, Drinkwater Jocelyn, Sousa David Cordeiro, Shah Vaibhav, Turner Angus W

Аннотация

CLINICAL RELEVANCE: The challenges of establishing retinal screening programs in rural settings may be mitigated by the emergence of deep-learning systems for early disease detection.

BACKGROUND: Deep-learning systems have demonstrated promising results in retinal disease detection and may be particularly useful in rural settings where accessibility remains a barrier to equitable service provision. This study aims to evaluate the real-world performance of Thirona RetCAD for the detection of referable diabetic retinopathy and age-related macular degeneration in a rural Australian population.

METHODS: Colour fundus images from participants with known diabetic retinopathy or age-related macular degeneration were randomly selected from ophthalmology clinics in four rural Australian centres. Grading was confirmed retrospectively by two retinal specialists. RetCAD produced a quantitative measure (0-100) for DR and AMD severity. The area under the ROC curve (AUC) was calculated. Sensitivity, specificity, and positive and negative predictive values were calculated at a pre-defined cut-point of ≥50.

RESULTS: A total of 150 images from 82 participants were included. The mean age (SD) was 64.0 (12.8) years. Seventy-nine (52.7%) eyes had evidence of referable DR, while 54 (36.0%) had evidence of referable AMD. The AUC for referable DR detection was 0.971 (95% CI 0.950-0.936) with a sensitivity of 86.1% (76.8%-92.0%) and a specificity of 91.6% (82.8%-96.1%) at the pre-defined cut-point. Using the Youden Index method, the optimal cut-point was 41.2 (sensitivity 93.7%, specificity 90.1%). The AUC for the detection of referable AMD was 0.880 (0.824-0.936). At the pre-defined cut-point sensitivity was 88.9% (77.8%-94.8%) and specificity was 66.7% (56.8%-75.3%). The optimal cut-point was 52.6 (sensitivity 87.0%, specificity 75.0%).

CONCLUSION: RetCAD is comparable with but does not outperform equivalent deep-learning systems for retinal disease detection. RetCAD may be suitable as an automated screening tool in a rural Australian setting.