MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12931-024-02671-y

Медицинская библиотека · Respiratory research · 2024

Prognosis of mechanically ventilated patients with COVID-19 after failure of high-flow nasal cannula: a retrospective cohort study.

Hyun Dong-Gon, Lee Su Yeon, Ahn Jee Hwan, Hong Sang-Bum, Lim Chae-Man, Koh Younsuck, Huh Jin Won

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

There is an argument whether the delayed intubation aggravate the respiratory failure in Acute respiratory distress syndrome (ARDS) patients with coronavirus disease 2019 (COVID-19). We aimed to investigate the effect of high-flow nasal cannula (HFNC) failure before mechanical ventilation on clinical outcomes in mechanically ventilated patients with COVID-19.

METHODS

This retrospective cohort study included mechanically ventilated patients who were diagnosed with COVID-19 and admitted to the intensive care unit (ICU) between February 2020 and December 2021 at Asan Medical Center. The patients were divided into HFNC failure (HFNC-F) and mechanical ventilation (MV) groups according to the use of HFNC before MV. The primary outcome of this study was to compare the worst values of ventilator parameters from day 1 to day 3 after mechanical ventilation between the two groups.

RESULTS

Overall, 158 mechanically ventilated patients with COVID-19 were included in this study: 107 patients (67.7%) in the HFNC-F group and 51 (32.3%) in the MV group. The two groups had similar profiles of ventilator parameter from day 1 to day 3 after mechanical ventilation, except of dynamic compliance on day 3 (28.38 mL/cmH2O in MV vs. 30.67 mL/H2O in HFNC-F, p = 0.032). In addition, the HFNC-F group (5.6%) had a lower rate of ECMO at 28 days than the MV group (17.6%), even after adjustment (adjusted hazard ratio, 0.30; 95% confidence interval, 0.11-0.83; p = 0.045).

CONCLUSIONS

Among mechanically ventilated COVID-19 patients, HFNC failure before mechanical ventilation was not associated with deterioration of respiratory failure.

Для цитирования: Hyun Dong-Gon, Lee Su Yeon, Ahn Jee Hwan, Hong Sang-Bum, Lim Chae-Man, Koh Younsuck, Huh Jin Won. Prognosis of mechanically ventilated patients with COVID-19 after failure of high-flow nasal cannula: a retrospective cohort study.. Respiratory research. 2024. DOI: 10.1186/s12931-024-02671-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.